How To Fix O3289 - AGA8:Warning code 26: Mole fract. of components is within the warn. range


O3289 - Overview

  • Message type: E = Error

  • Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)

  • Message number: 289

  • Message text: AGA8:Warning code 26: Mole fract. of components is within the warn. range

  • Show details Hide details
  • What causes this issue?

    The mole fraction of one of the components used for the gross method
    lies within the warning range of the AGA c-code. The compression factor
    will be calculated.
    The range is defined as follows, according to the AGA c-code
    documentation:

    The system issues an error message and will not allow you to continue with this transaction until the error is resolved.

    N2 (nitrogen) fraction > 0.2
    CO2 (carbon dioxide) fraction > 0.20
    H2(hydrogen) fraction > 0.0
    CO(carbon monoxide) fraction > 0.0

    System Response

    The QCI (Quantity Conversion Interface) continues processing if you
    confirm the warning message.

    How to fix this error?

    Procedure for System Administrators


    Error message extract from SAP system. Copyright SAP SE.


Smart SAP Assistant

  • What is the cause and solution for SAP error message O3289 - AGA8:Warning code 26: Mole fract. of components is within the warn. range ?
    The SAP error message O3289 AGA8: "Warning code 26: Mole fract. of components is within the warn. range" typically relates to the process of calculating or simulating chemical components in a system, particularly in the context of process engineering or chemical engineering applications within SAP.
    
    Cause: This warning indicates that the mole fraction of one or more components in a mixture is within a predefined warning range. This can occur due to: Component Concentration: The concentration of certain components may be too low or too high, leading to a warning about their mole fractions. Modeling Parameters: The parameters set for the simulation or calculation may not be optimal, causing the mole fractions to fall within a range that triggers a warning. Data Input Issues: Incorrect or incomplete data input for the components can lead to unexpected mole fractions. Thermodynamic Models: The thermodynamic model being used may not be suitable for the specific mixture, leading to warnings

    Already have an account? Login here!




Instant HelpGet instant SAP help. Sign up for our Free Essentials Plan.