Do you have any question about this error?
Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 287
Message text: AGA8:Warning code 23: Flowing (material) temp. is within warning range
The flowing temperature is within the warning range of the AGA c-code.
The compression factor will be calculated.
The warning range is, according to the AGA c-code documentation:
T/ ?Fahrenheit > 130 or T/ ?Fahrenheit < 32.0 ,
or approx.
T/ ?Celsius> 54.44 or T/ ?Celsius < 0.0 ,
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
The QCI (Quantity Conversion Interface) continues processing if you
confirm the message.
Error message extract from SAP system. Copyright SAP SE.
O3287
- AGA8:Warning code 23: Flowing (material) temp. is within warning range ?The SAP error message O3287 AGA8: Warning code 23 indicates that the flowing (material) temperature is within a warning range. This message typically arises in the context of process industries, particularly in scenarios involving temperature-sensitive materials.
Cause:
The warning is triggered when the temperature of a material being processed or transported is within a predefined range that is considered acceptable but may still warrant attention. This could be due to:
- Temperature Settings: The material's temperature is set to a range that is not optimal for processing or storage.
- Process Conditions: Variations in process conditions, such as ambient temperature or equipment performance, can lead to temperature fluctuations.
- Material Properties: Certain materials have specific temperature ranges that are critical for their stability and performance.
Solution:
To address this warning, consider the following steps:
- Review Temperature Settings: Check the temperature settings for the material in question. Ensure that they align with the recommended specifications for that material.
- Monitor Process Conditions: Investigate the process conditions to identify any anomalies that may be affecting the temperature. This could involve checking equipment performance, ambient conditions, or other influencing factors.
- Adjust Parameters: If necessary, adjust the parameters in the system to ensure that the material temperature remains within the optimal range.
- Consult Documentation: Refer to the material safety data sheets (MSDS) or other relevant documentation for specific temperature guidelines.
- Alert Personnel: If the temperature is approaching critical limits, alert relevant personnel to take corrective action.
Related Information:
By following these steps, you can effectively manage the warning and ensure that the material is handled safely and efficiently.
Get instant SAP help. Start your 7-day free trial now.
O3286
AGA8:Warning code 22: Flowing (material) pressure is within warning range
What causes this issue? The flowing pressure is within the warning range for the AGA c-code. The compression factor will be calculated. The warning ...
O3285
AGA8:Error code 18/38: Test (reference) pressure is out of range
What causes this issue? One of the test reference pressures is not within the valid range. The AGA c-code cannot calculate a compression factor.Syste...
O3288
AGA8:Warning code 24: Heating value is within the warning range
What causes this issue? The heating value is within the warning range of the AGA c-code. The compression factor will be calculated. The warning rang...
O3289
AGA8:Warning code 26: Mole fract. of components is within the warn. range
What causes this issue? The mole fraction of one of the components used for the gross method lies within the warning range of the AGA c-code. The com...
Click on this link to search all SAP messages.