Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 286
Message text: AGA8:Warning code 22: Flowing (material) pressure is within warning range
The flowing pressure is within the warning range for the AGA c-code.
The compression factor will be calculated.
The warning range is, according to the AGA c-code documentation:
P / PSIA > 1200 ,
or approx.
P / MPa > 8.274 .
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
The QCI (Quantity Conversion Interface) continues with processing if
you confirm the message.
Error message extract from SAP system. Copyright SAP SE.
O3286
- AGA8:Warning code 22: Flowing (material) pressure is within warning range ?The SAP error message O3286 AGA8: Warning code 22: "Flowing (material) pressure is within warning range" typically relates to the pressure conditions in a process or material flow scenario, often in the context of process industries such as oil and gas, chemicals, or manufacturing.
Cause: Pressure Monitoring: The warning indicates that the pressure of a flowing material is within a predefined warning range. This means that while the pressure is not at a critical level, it is approaching a threshold that may require attention. Configuration Settings: The warning may be triggered due to specific configuration settings in the SAP system that define acceptable pressure ranges for materials. Process Variability: Variations in the process, such as changes in temperature, flow rate, or material properties, can lead to fluctuations in pressure, causing the warning to be triggered.
Solution: Monitor Pressure Levels: Check the actual pressure readings against the defined warning thresholds. If the pressure is consistently near the
Get instant SAP help. Sign up for our Free Essentials Plan.
O3285
AGA8:Error code 18/38: Test (reference) pressure is out of range
What causes this issue? One of the test reference pressures is not within the valid range. The AGA c-code cannot calculate a compression factor.Syste...
O3284
AGA8:Error code 17/37: Test (reference) temperature is out of range
What causes this issue? One of the test reference temperatures is out of range. The AGA c-code cannot calculate a compression factor.System Response ...
O3287
AGA8:Warning code 23: Flowing (material) temp. is within warning range
What causes this issue? The flowing temperature is within the warning range of the AGA c-code. The compression factor will be calculated. The warnin...
O3288
AGA8:Warning code 24: Heating value is within the warning range
What causes this issue? The heating value is within the warning range of the AGA c-code. The compression factor will be calculated. The warning rang...