Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 288
Message text: AGA8:Warning code 24: Heating value is within the warning range
The heating value is within the warning range of the AGA c-code. The
compression factor will be calculated.
The warning range is, according to the AGA c-code documentation:
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
HV/ BTU per cubic foot > 1208 or HV/ BTU per cubic foot < 805.0 ,The QCI (Quantity Conversion Interface) continues processing if you
confirm the message.
Error message extract from SAP system. Copyright SAP SE.
O3288
- AGA8:Warning code 24: Heating value is within the warning range ?The SAP error message O3288 AGA8: Warning code 24 indicates that the heating value of a gas is within a specified warning range. This warning is typically related to the calculation of gas properties in the context of gas measurement and billing, particularly when using the AGA8 standard for gas properties.
Cause:
The warning is triggered when the calculated heating value of the gas falls within a predefined range that is considered acceptable but not optimal. This could be due to several factors, including:
- Gas Composition Variability: The composition of the gas may vary, leading to fluctuations in the heating value.
- Measurement Uncertainty: There may be uncertainties in the measurement of gas properties, such as temperature, pressure, or composition.
- Configuration Settings: The warning range may be set too broadly in the system configuration, leading to more frequent warnings.
Solution:
To address this warning, consider the following steps:
- Review Gas Composition: Check the gas composition data to ensure it is accurate and up-to-date. If there are discrepancies, correct them.
- Check Measurement Devices: Ensure that the measurement devices used for determining gas properties are calibrated and functioning correctly.
- Adjust Warning Range: If the warning range is too broad, you may want to adjust the configuration settings in SAP to set a more appropriate range for your specific gas types.
- Consult Documentation: Refer to the SAP documentation or AGA8 standards for guidance on acceptable heating values and how to interpret the warning.
- Monitor Trends: Keep an eye on the heating value trends over time to identify any patterns or persistent issues that may need further investigation.
Related Information:
By following these steps, you should be able to address the warning and ensure that your gas measurement processes are accurate and reliable.
Get instant SAP help. Start your 7-day free trial now.
O3287
AGA8:Warning code 23: Flowing (material) temp. is within warning range
What causes this issue? The flowing temperature is within the warning range of the AGA c-code. The compression factor will be calculated. The warnin...
O3286
AGA8:Warning code 22: Flowing (material) pressure is within warning range
What causes this issue? The flowing pressure is within the warning range for the AGA c-code. The compression factor will be calculated. The warning ...
O3289
AGA8:Warning code 26: Mole fract. of components is within the warn. range
What causes this issue? The mole fraction of one of the components used for the gross method lies within the warning range of the AGA c-code. The com...
O3290
AGA8:Warning code 25: natural gas relative density within warning range
What causes this issue? The test relative density is within the warning range of the AGA c-code. The compression factor will be calculated. The warni...
Click on this link to search all SAP messages.