Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 290
Message text: AGA8:Warning code 25: natural gas relative density within warning range
The test relative density is within the warning range of the AGA
c-code. The compression factor will be calculated.
The warning range is defined as follows, according to the AGA c-code
documentation:
rel.density > 0.8
or
rel. density < 0.55
The QCI (Quantity Conversion Interface) continues processing after you
confirm this message.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
O3290
- AGA8:Warning code 25: natural gas relative density within warning range ?The SAP error message O3290 AGA8: Warning code 25 indicates that the relative density of natural gas is within a warning range, which may not necessarily indicate a critical error but rather a condition that requires attention. Here’s a breakdown of the cause, potential solutions, and related information:
Cause: Relative Density Measurement: The relative density of natural gas is a critical parameter in gas measurement and calculations. A warning code indicates that the measured relative density is within a range that may not be optimal or expected. Data Input Issues: The warning could arise from incorrect or imprecise data input regarding the gas composition or conditions. Gas Composition Variability: Natural gas can vary in composition, and changes in the composition can lead to variations in relative density. Calibration Issues: Instruments used to measure the relative density may need calibration or maintenance.
Solution: Review Input Data: Check the input data for the relative density and ensure that it
Get instant SAP help. Sign up for our Free Essentials Plan.
O3289
AGA8:Warning code 26: Mole fract. of components is within the warn. range
What causes this issue? The mole fraction of one of the components used for the gross method lies within the warning range of the AGA c-code. The com...
O3288
AGA8:Warning code 24: Heating value is within the warning range
What causes this issue? The heating value is within the warning range of the AGA c-code. The compression factor will be calculated. The warning rang...
O3291
AGA8:Error code 1: Pressure has a negative derivative
What causes this issue? The AGA c-code cannot calculate a compression factor.System Response The QCI (Quantity Conversion Interface) stops processin...
O3292
AGA8:Warning code 2: Density in bracket exceeds the maximum
What causes this issue? The AGA c-code will use the default density; the compression factor will be calculated.System Response The QCI (Quantity Co...
Click on this link to search all SAP messages.