Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 284
Message text: AGA8:Error code 17/37: Test (reference) temperature is out of range
One of the test reference temperatures is out of range. The AGA c-code
cannot calculate a compression factor.
The QCI (Quantity Conversion Interface) stops processing.
Check that all test temperatures are within the valid range, which is,
according to the AGA c-code documentation:
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
32.0 < T / ?Fahrenheit < 77.0Error message extract from SAP system. Copyright SAP SE.
O3284
- AGA8:Error code 17/37: Test (reference) temperature is out of range ?The SAP error message O3284 AGA8: Error code 17/37 indicates that there is an issue with the test (reference) temperature being out of the acceptable range during a quality inspection or testing process. This error typically arises in the context of quality management (QM) within SAP, particularly when dealing with material inspections or tests that require specific temperature conditions.
Cause:
- Temperature Settings: The reference temperature set for the test may be outside the defined limits in the material specification or inspection plan.
- Material Specifications: The material being tested may have specific temperature requirements that are not being met.
- Calibration Issues: The equipment used for testing may not be calibrated correctly, leading to inaccurate temperature readings.
- Environmental Factors: External conditions affecting the testing environment may cause the temperature to deviate from the required range.
Solution:
- Check Inspection Plan: Review the inspection plan associated with the material to ensure that the reference temperature is correctly defined and within the acceptable range.
- Adjust Temperature Settings: If the reference temperature is indeed out of range, adjust it to fall within the specified limits.
- Verify Equipment Calibration: Ensure that the testing equipment is properly calibrated and functioning correctly. If necessary, recalibrate the equipment.
- Environmental Control: Make sure that the testing environment is controlled and that the temperature is maintained within the required range during testing.
- Consult Documentation: Refer to the material specifications and quality standards to ensure compliance with temperature requirements.
Related Information:
By following these steps, you should be able to identify the cause of the error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
O3283
AGA8:Error code 16: Mole fraction of components is not in valid range
What causes this issue? One of the mole fractions of the components for the gross method is not within the valid range. The AGA c-code can not calcul...
O3282
AGA8:Error code 15: Natural gas relative density is not in valid range
What causes this issue? The test relative density is not within the valid range for the AGA c-code routine. No compression factor will be calculated....
O3285
AGA8:Error code 18/38: Test (reference) pressure is out of range
What causes this issue? One of the test reference pressures is not within the valid range. The AGA c-code cannot calculate a compression factor.Syste...
O3286
AGA8:Warning code 22: Flowing (material) pressure is within warning range
What causes this issue? The flowing pressure is within the warning range for the AGA c-code. The compression factor will be calculated. The warning ...
Click on this link to search all SAP messages.