Do you have any question about this error?
Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 291
Message text: AGA8:Error code 1: Pressure has a negative derivative
The AGA c-code cannot calculate a compression factor.
The QCI (Quantity Conversion Interface) stops processing.
Check the relevant parameters for the detailed method of the AGA c-code
routine.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
O3291
- AGA8:Error code 1: Pressure has a negative derivative ?The SAP error message O3291 AGA8: Error code 1: "Pressure has a negative derivative" typically relates to issues in the calculation of gas flow or pressure in a gas measurement context, particularly when using the AGA8 gas flow calculation method. This error indicates that the pressure values being processed are not behaving as expected, specifically that the pressure is decreasing over time when it should be increasing or remaining stable.
Causes:
- Data Input Issues: The input data for pressure measurements may be incorrect or inconsistent. This could be due to faulty sensors, incorrect calibration, or data entry errors.
- Measurement Errors: There may be physical issues with the measurement devices, such as blockages, leaks, or malfunctions that lead to erroneous pressure readings.
- Calculation Errors: The algorithm used for calculating gas flow may be encountering unexpected values or conditions that lead to negative derivatives in pressure.
- System Configuration: Incorrect configuration settings in the SAP system or the measurement devices can lead to improper data processing.
Solutions:
- Check Input Data: Verify the accuracy of the pressure data being input into the system. Ensure that all sensors are calibrated correctly and functioning properly.
- Inspect Measurement Devices: Physically inspect the measurement devices for any signs of malfunction, blockage, or leaks. Replace or repair any faulty equipment.
- Review Calculation Logic: If you have access to the calculation logic or algorithms, review them to ensure they are set up correctly and are handling the data appropriately.
- Adjust System Configuration: Review the configuration settings in the SAP system related to gas measurement and ensure they are set correctly for your specific application.
- Consult Documentation: Refer to SAP documentation or support resources for specific guidance on handling this error message and any related troubleshooting steps.
Related Information:
By addressing the potential causes and following the suggested solutions, you should be able to resolve the error message O3291 effectively.
Get instant SAP help. Start your 7-day free trial now.
O3290
AGA8:Warning code 25: natural gas relative density within warning range
What causes this issue? The test relative density is within the warning range of the AGA c-code. The compression factor will be calculated. The warni...
O3289
AGA8:Warning code 26: Mole fract. of components is within the warn. range
What causes this issue? The mole fraction of one of the components used for the gross method lies within the warning range of the AGA c-code. The com...
O3292
AGA8:Warning code 2: Density in bracket exceeds the maximum
What causes this issue? The AGA c-code will use the default density; the compression factor will be calculated.System Response The QCI (Quantity Co...
O3293
AGA8:Error code 3: Maximum iterations exceeded in bracket
What causes this issue? The AGA c-code has exceeded the number of iteratons in one of its subroutines. It cannot calculate a compression factor.Syste...
Click on this link to search all SAP messages.