How To Fix O3282 - AGA8:Error code 15: Natural gas relative density is not in valid range


SAP Error Message - Details

  • Message type: E = Error

  • Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)

  • Message number: 282

  • Message text: AGA8:Error code 15: Natural gas relative density is not in valid range

  • Show details Hide details
  • What causes this issue?

    The test relative density is not within the valid range for the AGA
    c-code routine. No compression factor will be calculated.

    System Response

    The QCI (Quantity Conversion Interface) stops processing.

    How to fix this error?

    Enter a value within the valid range. According to the AGA c-code
    documentation, the valid range is:
    0.55 < rel.density < 0.870

    The system issues an error message and will not allow you to continue with this transaction until the error is resolved.

    Procedure for System Administrators


    Error message extract from SAP system. Copyright SAP SE.


Smart SAP Assistant

  • What is the cause and solution for SAP error message O3282 - AGA8:Error code 15: Natural gas relative density is not in valid range ?

    The SAP error message O3282 AGA8: Error code 15 indicates that the relative density of natural gas being processed is outside the valid range. This error typically occurs in the context of gas measurement and processing, particularly when using the AGA8 standard for gas volume correction.

    Cause:

    1. Invalid Input Data: The relative density value provided for the natural gas may be incorrect or not within the acceptable range (usually between 0.5 and 1.0 for natural gas).
    2. Data Entry Errors: There may have been a typographical error or incorrect data entry when inputting the relative density.
    3. System Configuration: The system may not be configured correctly to handle the specific characteristics of the gas being measured.
    4. Measurement Issues: The measurement equipment may be malfunctioning or not calibrated correctly, leading to inaccurate density readings.

    Solution:

    1. Verify Input Data: Check the relative density value entered in the system. Ensure it is within the valid range (typically between 0.5 and 1.0).
    2. Correct Data Entry: If an error is found in the data entry, correct it and reprocess the transaction.
    3. Review System Configuration: Ensure that the SAP system is configured correctly for the type of gas being measured. This may involve checking settings related to gas properties.
    4. Calibration of Equipment: If the relative density is measured using equipment, ensure that the equipment is properly calibrated and functioning correctly.
    5. Consult Documentation: Refer to the SAP documentation or AGA8 standards for further guidance on acceptable values and configurations.

    Related Information:

    • AGA8 Standard: The AGA8 standard provides guidelines for calculating the properties of natural gas, including volume correction factors based on temperature, pressure, and gas composition.
    • SAP Modules: This error may be encountered in modules related to gas measurement, such as SAP IS-Oil or SAP Utilities.
    • Support: If the issue persists after checking the above points, consider reaching out to SAP support or consulting with a technical expert familiar with gas measurement in SAP systems.

    By addressing the root cause of the error and ensuring that all data and configurations are correct, you should be able to resolve the O3282 error effectively.

    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Start your 7-day free trial now.


Related SAP Error Messages

Click the links below to see the following related messages:

Click on this link to search all SAP messages.


Rating