Do you have any question about this error?
Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 282
Message text: AGA8:Error code 15: Natural gas relative density is not in valid range
The test relative density is not within the valid range for the AGA
c-code routine. No compression factor will be calculated.
The QCI (Quantity Conversion Interface) stops processing.
Enter a value within the valid range. According to the AGA c-code
documentation, the valid range is:
0.55 < rel.density < 0.870
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
O3282
- AGA8:Error code 15: Natural gas relative density is not in valid range ?The SAP error message O3282 AGA8: Error code 15 indicates that the relative density of natural gas being processed is outside the valid range. This error typically occurs in the context of gas measurement and processing, particularly when using the AGA8 standard for gas volume correction.
Cause:
- Invalid Input Data: The relative density value provided for the natural gas may be incorrect or not within the acceptable range (usually between 0.5 and 1.0 for natural gas).
- Data Entry Errors: There may have been a typographical error or incorrect data entry when inputting the relative density.
- System Configuration: The system may not be configured correctly to handle the specific characteristics of the gas being measured.
- Measurement Issues: The measurement equipment may be malfunctioning or not calibrated correctly, leading to inaccurate density readings.
Solution:
- Verify Input Data: Check the relative density value entered in the system. Ensure it is within the valid range (typically between 0.5 and 1.0).
- Correct Data Entry: If an error is found in the data entry, correct it and reprocess the transaction.
- Review System Configuration: Ensure that the SAP system is configured correctly for the type of gas being measured. This may involve checking settings related to gas properties.
- Calibration of Equipment: If the relative density is measured using equipment, ensure that the equipment is properly calibrated and functioning correctly.
- Consult Documentation: Refer to the SAP documentation or AGA8 standards for further guidance on acceptable values and configurations.
Related Information:
By addressing the root cause of the error and ensuring that all data and configurations are correct, you should be able to resolve the O3282 error effectively.
Get instant SAP help. Start your 7-day free trial now.
O3281
AGA8:Error code 14: Heating value is not within the valid range
What causes this issue? The test gross heating value HV is not within the valid range for the AGA c-code.System Response The QCI (Quantity Conversio...
O3280
AGA8:Error code 12: Flowing pressure (material pressure) is out of range
What causes this issue? The flowing pressure is not within the valid range for the AGA c-code.System Response The QCI (Quantity Conversion Interface...
O3283
AGA8:Error code 16: Mole fraction of components is not in valid range
What causes this issue? One of the mole fractions of the components for the gross method is not within the valid range. The AGA c-code can not calcul...
O3284
AGA8:Error code 17/37: Test (reference) temperature is out of range
What causes this issue? One of the test reference temperatures is out of range. The AGA c-code cannot calculate a compression factor.System Response ...
Click on this link to search all SAP messages.