Do you have any question about this error?
Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 281
Message text: AGA8:Error code 14: Heating value is not within the valid range
The test gross heating value HV is not within the valid range for the
AGA c-code.
The QCI (Quantity Conversion Interface) stops processing.
Enter a test gross heating value (HV) in the correct range.
The valid range is, according to the AGA c-code documentation:
477 < HV/ BTU per cubic foot < 1211 ,
or
17.7725 < HV / MJ per cubic meter < 45.12 .
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
O3281
- AGA8:Error code 14: Heating value is not within the valid range ?The SAP error message O3281 AGA8: Error code 14: Heating value is not within the valid range typically occurs in the context of gas measurement and processing within SAP's Advanced Gas Analysis (AGA) module. This error indicates that the heating value of the gas being processed does not fall within the acceptable range defined by the system.
Cause:
- Invalid Input Data: The heating value provided for the gas may be incorrect or not formatted properly.
- Configuration Issues: The system may not be configured correctly to accept the heating values for the specific type of gas being analyzed.
- Data Entry Errors: There may be typographical errors or incorrect units of measurement used when entering the heating value.
- Outdated or Incorrect Master Data: The master data for the gas type may not be updated or may contain incorrect ranges for heating values.
Solution:
- Verify Input Data: Check the heating value being entered to ensure it is accurate and within the expected range. The valid range should be defined in the system documentation or configuration.
- Check Configuration: Review the configuration settings in the AGA module to ensure that the heating value ranges are set correctly for the type of gas being processed.
- Correct Data Entry: Ensure that the heating value is entered in the correct format and units. For example, if the system expects heating values in BTU or MJ, ensure that the values are provided accordingly.
- Update Master Data: If the heating value is valid but still triggers the error, check the master data for the gas type in question. Update the master data to reflect the correct heating value ranges if necessary.
- Consult Documentation: Refer to SAP documentation or help resources for specific details on valid heating value ranges for different gas types.
- Contact Support: If the issue persists after checking the above points, consider reaching out to SAP support for further assistance.
Related Information:
By following these steps, you should be able to identify the cause of the error and implement a solution to resolve it.
Get instant SAP help. Start your 7-day free trial now.
O3280
AGA8:Error code 12: Flowing pressure (material pressure) is out of range
What causes this issue? The flowing pressure is not within the valid range for the AGA c-code.System Response The QCI (Quantity Conversion Interface...
O3279
AGA8:Error code 13: Flowing temperature (mat. temperature)is out of range
What causes this issue? The flowing temperature is not within the valid range for the AGA c-code.System Response The QCI (Quantity Conversion Interf...
O3282
AGA8:Error code 15: Natural gas relative density is not in valid range
What causes this issue? The test relative density is not within the valid range for the AGA c-code routine. No compression factor will be calculated....
O3283
AGA8:Error code 16: Mole fraction of components is not in valid range
What causes this issue? One of the mole fractions of the components for the gross method is not within the valid range. The AGA c-code can not calcul...
Click on this link to search all SAP messages.