Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 283
Message text: AGA8:Error code 16: Mole fraction of components is not in valid range
One of the mole fractions of the components for the gross method is not
within the valid range. The AGA c-code can not calculate a compression
factor.
The QCI (Quantity Conversion Interface) stops processing
Check that all fractions are within the specified ranges, according to
the AGA c-code documentation:
Nitrogen (N2): 0.0 < N2 < 0.50
Carbon dioxide (CO2) : 0.0 < CO2 < 0.30
Hydrogen (H2): 0.0 < H2 < 0.10
Carbon monoxide (CO) 0.0 < CO < 0.03
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
O3283
- AGA8:Error code 16: Mole fraction of components is not in valid range ?The SAP error message O3283 AGA8: Error code 16: "Mole fraction of components is not in valid range" typically occurs in the context of process engineering or chemical composition calculations within SAP systems, particularly when dealing with gas mixtures or chemical components.
Cause: This error indicates that the mole fractions of the components in a mixture do not sum up to 1 or that one or more mole fractions are outside the valid range (0 to 1). In a valid mixture, the mole fraction of each component should be a non-negative number, and the total of all mole fractions should equal 1.
Solution: To resolve this error, you should: Check Component Values: Review the mole fractions of all components in the mixture. Ensure that: Each mole fraction is between 0 and 1. The sum of all mole fractions equals 1. Adjust Values: If any mole fraction is incorrect, adjust the values accordingly. For example, if you have three
Get instant SAP help. Sign up for our Free Essentials Plan.
O3282
AGA8:Error code 15: Natural gas relative density is not in valid range
What causes this issue? The test relative density is not within the valid range for the AGA c-code routine. No compression factor will be calculated....
O3281
AGA8:Error code 14: Heating value is not within the valid range
What causes this issue? The test gross heating value HV is not within the valid range for the AGA c-code.System Response The QCI (Quantity Conversio...
O3284
AGA8:Error code 17/37: Test (reference) temperature is out of range
What causes this issue? One of the test reference temperatures is out of range. The AGA c-code cannot calculate a compression factor.System Response ...
O3285
AGA8:Error code 18/38: Test (reference) pressure is out of range
What causes this issue? One of the test reference pressures is not within the valid range. The AGA c-code cannot calculate a compression factor.Syste...
Click on this link to search all SAP messages.