Do you have any question about this error?
Message type: E = Error
Message class: CM_CBESCOM - Message Class for ESComXML Outbound Processing
Message number: 096
Message text: ESComXML file does not exist
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
The ESComXML file could not be displayed as the report does not contain
an ESComXML file.
The ESComXML file is not displayed.
Generate the report again. Check in <DS:TRAN.CG50>Report Management </>
if an ESComXML file was created for the report. If this is the case,
contact your system administrator.
If the ESComXML file does not exist for the report, check the
corresponding generation log.
Check if the ESComXML file exists in the document &V1& in the document
management system. Make sure that an ESComXML file has been stored in
the original file 2 (application ZIP or XML).
Error message extract from SAP system. Copyright SAP SE.
CM_CBESCOM096
- ESComXML file does not exist ?The SAP error message CM_CBESCOM096 indicates that the ESComXML file does not exist. This error typically occurs in the context of SAP's Enterprise Services (ES) or when dealing with communication between different systems or components in an SAP landscape.
Cause:
- File Not Generated: The ESComXML file may not have been generated due to a failure in the preceding process or job.
- Incorrect Path: The system may be looking for the file in the wrong directory or path.
- File Deletion: The file may have been deleted or moved after it was created.
- Permissions Issue: There may be insufficient permissions to access the directory where the file is supposed to be located.
- Configuration Issues: There may be misconfigurations in the settings related to the ESCom or the communication setup.
Solution:
- Check File Generation: Verify if the process that is supposed to generate the ESComXML file has run successfully. If not, investigate the logs for any errors.
- Verify File Path: Ensure that the path specified for the ESComXML file is correct. You can check the configuration settings in the relevant transaction codes (like SOAMANAGER for web services).
- Check for File Existence: Manually check the directory where the file is expected to be located to see if it exists.
- Review Permissions: Ensure that the user or service account running the process has the necessary permissions to create and access files in the specified directory.
- Reconfigure Settings: If there are configuration issues, review the settings related to the ESCom and correct any discrepancies.
- Consult Logs: Look into the application logs (transaction SLG1) for any additional error messages or warnings that could provide more context about the issue.
Related Information:
If the issue persists after following these steps, consider reaching out to SAP support for further assistance.
Get instant SAP help. Start your 7-day free trial now.
CM_CBESCOM095
DUNS code not assigned to sales organization &1
What causes this issue? The determination of the DUNS code for sales organiziation &V1& failed.System Response The system issues an error me...
CM_CBESCOM094
E-mail address not assigned to sales organization &1
Link muss auf neue Customizing AktivitSt gehenWhat causes this issue? The determination of the e-mail address for sales organiziation &V1& f...
CM_CBESCOM097
Communication type of recipient is not valid
Schirmnachricht Nummer 082 The system issues an error message and will not allow you to continue with this transaction until the error is resolved. W...
CM_CBESCOM098
Output device could not be determined
Schirmnachricht Nummer 082 The system issues an error message and will not allow you to continue with this transaction until the error is resolved. W...
Click on this link to search all SAP messages.