Do you have any question about this error?
Message type: E = Error
Message class: AH - IS-U billing (master data)
Message number: 813
Message text: Device &1 reg. &2 period &3 - &4: error in register relationship
A gas procedure is to be carried out for the register. For this
procedure, the volume correction factor component is determined by a
special procedure that uses the register relationship "volume
correction factor calculation".
For the specified period, no corresponding device/register representing
the standard volume meter could be found for this device/register.
Proceed as follows:
Check the register relationship for the specified device/register and
period, and correct the register relationship if necessary.
If this does not solve the problem, an internal error may have
occurred. In this case, contact SAP.
Error message extract from SAP system. Copyright SAP SE.
AH813
- Device &1 reg. &2 period &3 - &4: error in register relationship ?The SAP error message AH813 indicates an issue with the register relationship for a specific device in the context of asset accounting or similar modules. This error typically arises when there is a mismatch or inconsistency in the configuration of asset registers or when the system is unable to properly relate the device to its corresponding registers.
Cause:
- Configuration Issues: The device may not be properly configured in the system, leading to inconsistencies in how it relates to the registers.
- Data Inconsistencies: There may be missing or incorrect data in the asset master records or register settings.
- Period Issues: The specified periods may not be valid for the device or the registers, leading to errors in processing.
- Authorization Issues: Lack of proper authorizations to access or modify the registers can also lead to this error.
Solution:
- Check Configuration: Review the configuration settings for the device and ensure that it is correctly set up in the system. This includes checking the asset class, depreciation areas, and register settings.
- Validate Data: Ensure that all necessary data for the asset and its registers are complete and accurate. This includes checking the asset master data and any related records.
- Review Period Settings: Verify that the periods specified in the error message are valid and that the device is active during those periods.
- Authorization Check: Ensure that the user has the necessary authorizations to access and modify the registers associated with the device.
- Consult Documentation: Refer to SAP documentation or help resources for specific guidance on the error message and related configuration settings.
Related Information:
By following these steps, you should be able to identify and resolve the underlying cause of the AH813 error message in SAP.
Get instant SAP help. Start your 7-day free trial now.
AH812
Device &1 reg. &2 period &3 - &4: operating volume cannot be determined
What causes this issue? A gas procedure is to be carried out for the register. For this procedure, the volume correction factor component is determin...
AH811
Device &1 reg. &2 period &3 - &4: standard volume cannot be determined
What causes this issue? A gas procedure is to be carried out for the register. For this procedure, the volume correction factor component is determin...
AH814
Device &1 reg. &2 period &3 - &4: vol. corr. factor cannot be determined
What causes this issue? A gas procedure is to be carried out for a register. For this procedure, the volume correction factor procedure component is ...
AH815
Device &1 reg. &2 period &3 - &4: error in register relationship
What causes this issue? A gas procedure is to be carried out for a register. For this procedure, the volume correction factor component is determined...
Click on this link to search all SAP messages.