Do you have any question about this error?
Message type: E = Error
Message class: AH - IS-U billing (master data)
Message number: 815
Message text: Device &1 reg. &2 period &3 - &4: error in register relationship
A gas procedure is to be carried out for a register. For this
procedure, the volume correction factor component is determined by a
special procedure that uses the register relationship "volume corre
ction factor relationship". For the specified period, no corresponding
device/register having the operation code "Register adopts volume
correction factor" could be found for this device/register.
Proceed as follows:
Check the register relationship for the specified device/register and
period, and correct the register relationship if necessary.
If this does not solve the problem, an internal error may have
occurred. In this case, contact SAP.
Error message extract from SAP system. Copyright SAP SE.
AH815
- Device &1 reg. &2 period &3 - &4: error in register relationship ?The SAP error message AH815 indicates an issue with the register relationship for a device in the context of device management, particularly in the area of utility billing or meter data management. This error typically arises when there is a mismatch or inconsistency in the configuration of the device registers or their relationships.
Cause:
Incorrect Configuration: The device registers may not be correctly configured in the system. This could include issues such as:
- Missing or incorrect register types.
- Incorrect assignment of registers to the device.
- Inconsistent data in the register relationships.
Data Inconsistencies: There may be inconsistencies in the data for the specified period, such as:
- Missing readings for the specified period.
- Conflicting data entries for the same period.
Period Issues: The specified period may not be valid for the device or register, leading to errors in processing.
Solution:
Check Device Configuration: Review the configuration of the device and its registers in the SAP system. Ensure that:
- All required registers are correctly assigned to the device.
- The register types are appropriate and correctly defined.
Validate Data Entries: Check the data entries for the specified period. Ensure that:
- There are no missing readings.
- There are no conflicting entries for the same period.
Review Register Relationships: Ensure that the relationships between registers are correctly defined. This may involve:
- Checking the relationship settings in the device management module.
- Ensuring that the registers are linked correctly according to the business logic.
Consult Documentation: Refer to SAP documentation or help resources for specific guidance on the error message and its resolution.
Testing: After making the necessary adjustments, test the device and register functionality to ensure that the error is resolved.
Related Information:
Transaction Codes: You may need to use specific transaction codes in SAP to access device management settings, such as:
SAP Notes: Check for any relevant SAP Notes that may provide additional insights or patches related to this error.
Support: If the issue persists after troubleshooting, consider reaching out to SAP support or your internal SAP team for further assistance.
By following these steps, you should be able to identify and resolve the underlying cause of the AH815 error message in SAP.
Get instant SAP help. Start your 7-day free trial now.
AH814
Device &1 reg. &2 period &3 - &4: vol. corr. factor cannot be determined
What causes this issue? A gas procedure is to be carried out for a register. For this procedure, the volume correction factor procedure component is ...
AH813
Device &1 reg. &2 period &3 - &4: error in register relationship
What causes this issue? A gas procedure is to be carried out for the register. For this procedure, the volume correction factor component is determin...
AH816
Dev. &1 reg. &2 per. &3 - &4: VCF to be transferred cannot be determined
What causes this issue? A gas procedure is to be carried out for a register. For this procedure, the volume correction factor component is determined...
AH817
Weighting key &1 division cat. &2: energy feeding table incomplete
What causes this issue? There are no entries in the <LS>Define Energy Feedings per Period</> table for weighting key &v1& and div...
Click on this link to search all SAP messages.