Do you have any question about this error?
Message type: E = Error
Message class: AH - IS-U billing (master data)
Message number: 817
Message text: Weighting key &1 division cat. &2: energy feeding table incomplete
There are no entries in the <LS>Define Energy Feedings per Period</>
table for weighting key &v1& and division category &v2&.
Maintain this table.
Error message extract from SAP system. Copyright SAP SE.
AH817
- Weighting key &1 division cat. &2: energy feeding table incomplete ?The SAP error message AH817 indicates that there is an issue with the energy feeding table related to a specific weighting key and division category. This error typically arises in the context of energy management or cost allocation processes within SAP, particularly in modules like SAP IS-U (Industry Solution for Utilities) or SAP PM (Plant Maintenance).
Cause:
The error message AH817 is triggered when the system cannot find a complete entry in the energy feeding table for the specified weighting key and division category. This can happen due to several reasons:
- Incomplete Configuration: The energy feeding table may not have been fully configured for the specified weighting key and division category.
- Missing Data: There may be missing entries or incorrect data in the energy feeding table that prevents the system from processing the request.
- Incorrect Weighting Key or Division Category: The weighting key or division category being referenced may not exist or may be incorrectly specified in the transaction.
Solution:
To resolve the AH817 error, you can take the following steps:
Check Configuration:
- Navigate to the configuration settings for the energy feeding table in SAP.
- Ensure that the relevant entries for the specified weighting key and division category are present and correctly configured.
Update Energy Feeding Table:
- If entries are missing, you may need to add them. This can typically be done through transaction codes like
SPRO
(for configuration) or specific transaction codes related to energy management.- Ensure that all required fields are filled out correctly.
Verify Weighting Key and Division Category:
- Double-check the weighting key and division category being used in the transaction that triggered the error.
- Make sure they are valid and correspond to the entries in the energy feeding table.
Consult Documentation:
- Review SAP documentation or help files related to energy management and the specific modules you are using to ensure you are following the correct procedures.
Testing:
- After making the necessary changes, test the transaction again to see if the error persists.
Seek Help from SAP Support:
- If the issue continues after checking the configuration and data, consider reaching out to SAP support for further assistance.
Related Information:
SPRO
, SE11
(Data Dictionary), and others that may help you navigate the configuration and data management aspects of SAP.By following these steps, you should be able to identify and resolve the underlying issue causing the AH817 error in SAP.
Get instant SAP help. Start your 7-day free trial now.
AH816
Dev. &1 reg. &2 per. &3 - &4: VCF to be transferred cannot be determined
What causes this issue? A gas procedure is to be carried out for a register. For this procedure, the volume correction factor component is determined...
AH815
Device &1 reg. &2 period &3 - &4: error in register relationship
What causes this issue? A gas procedure is to be carried out for a register. For this procedure, the volume correction factor component is determined...
AH818
Enter gas pressure correction only for gas pressure determination
What causes this issue? You should set the <ZH>Gas pressure correction</> indicator only if you have also selected the <ZH>Gas pres...
AH819
Initialization of controls in rate steps started on &1 at &2
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.