Message type: E = Error
Message class: RSCRT - Near-To-Real-Time Messages
Message number: 387
Message text: DTP &1 of DataSource &2 for InfoProvider &3 has no instance
The data transfer process &V1& from DataSource &V2& to InfoProvider &V3&
appears to be faulty. The method FACTORY of class CL_RSBK_DTP does not
provide a valid instance of the data transfer process.
The RDA damon does not execute the data transfer process &V1&. No data
is loaded by RDA from DataSource &V2& into InfoProvider &V3&.
Check the DTP &V1& in transaction RSDTP or in the Data Warehousing
Workbench.
Error message extract from SAP system. Copyright SAP SE.
RSCRT387
- DTP &1 of DataSource &2 for InfoProvider &3 has no instance ?The SAP error message RSCRT387 indicates that there is an issue with a Data Transfer Process (DTP) in SAP BW (Business Warehouse). Specifically, it means that the DTP for a given DataSource does not have any instances available for the specified InfoProvider. This can occur for several reasons, and understanding the cause is essential for resolving the issue.
Causes:
- No Data Loaded: The DataSource may not have any data loaded into the InfoProvider, which means there are no instances available for the DTP to process.
- Incorrect DTP Configuration: The DTP might be incorrectly configured, leading to it not being able to find or access the data.
- DataSource Issues: The DataSource itself may be inactive or not properly set up, preventing data from being extracted.
- InfoProvider Issues: The InfoProvider may not be correctly defined or may not be compatible with the DataSource.
- Data Selection Criteria: The selection criteria defined in the DTP may be too restrictive, resulting in no data being selected for processing.
Solutions:
- Check Data Loading: Verify if data has been successfully loaded into the InfoProvider. You can do this by checking the data in the InfoProvider directly.
- Review DTP Configuration: Go through the DTP settings to ensure that it is correctly configured. Check the source and target settings, as well as any transformation rules.
- Validate DataSource: Ensure that the DataSource is active and properly configured. You can check the DataSource in the Data Warehousing Workbench (transaction RSA1).
- Inspect InfoProvider: Make sure that the InfoProvider is correctly defined and that it is compatible with the DataSource. Check for any inconsistencies or errors in the InfoProvider setup.
- Adjust Selection Criteria: If the DTP has selection criteria, consider relaxing them to see if data can be retrieved. This can help identify if the issue is related to overly restrictive filters.
- Check for Errors in Data Transfer: Look for any error messages or logs related to the data transfer process that might provide additional insights into the issue.
Related Information:
By following these steps, you should be able to identify the root cause of the RSCRT387 error and implement the necessary solutions to resolve it.
Get instant SAP help. Sign up for our Free Essentials Plan.
RSCRT386
DTP &1 of DataSource &2 for InfoProvider &3 has no active version
What causes this issue? The data transfer process &V1& from the DataSource &V2& to the InfoProvider &V3& is delivered as DTP ...
RSCRT385
DTP &1 of DataSource &2 for InfoProvider &3 is not assigned
What causes this issue? The data transfer process &V1& from the DataSource &V2& to the InfoProvider &V3& is delivered as DTP ...
RSCRT388
Background job &1 terminates continuously since an hour
What causes this issue? The background job &V1& should execute a daemon for real-time data acquisition (RDA), but it hs been continuously ter...
RSCRT389
Daemon &1 terminated correctly during server shutdown
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.