Do you have any question about this error?
Message type: E = Error
Message class: RSCRT - Near-To-Real-Time Messages
Message number: 387
Message text: DTP &1 of DataSource &2 for InfoProvider &3 has no instance
The data transfer process &V1& from DataSource &V2& to InfoProvider &V3&
appears to be faulty. The method FACTORY of class CL_RSBK_DTP does not
provide a valid instance of the data transfer process.
The RDA damon does not execute the data transfer process &V1&. No data
is loaded by RDA from DataSource &V2& into InfoProvider &V3&.
Check the DTP &V1& in transaction RSDTP or in the Data Warehousing
Workbench.
Error message extract from SAP system. Copyright SAP SE.
RSCRT387
- DTP &1 of DataSource &2 for InfoProvider &3 has no instance ?The SAP error message RSCRT387 indicates that there is an issue with a Data Transfer Process (DTP) in SAP BW (Business Warehouse). Specifically, it means that the DTP for a given DataSource does not have any instances available for the specified InfoProvider. This can occur for several reasons, and understanding the cause is essential for resolving the issue.
Causes:
- No Data Loaded: The DataSource may not have any data loaded into the InfoProvider, which means there are no instances available for the DTP to process.
- Incorrect DTP Configuration: The DTP might be incorrectly configured, leading to it not being able to find or access the data.
- DataSource Issues: The DataSource itself may be inactive or not properly set up, preventing data from being extracted.
- InfoProvider Issues: The InfoProvider may not be correctly defined or may not be compatible with the DataSource.
- Data Selection Criteria: The selection criteria defined in the DTP may be too restrictive, resulting in no data being selected for processing.
Solutions:
- Check Data Loading: Verify if data has been successfully loaded into the InfoProvider. You can do this by checking the data in the InfoProvider directly.
- Review DTP Configuration: Go through the DTP settings to ensure that it is correctly configured. Check the source and target settings, as well as any transformation rules.
- Validate DataSource: Ensure that the DataSource is active and properly configured. You can check the DataSource in the Data Warehousing Workbench (transaction RSA1).
- Inspect InfoProvider: Make sure that the InfoProvider is correctly defined and that it is compatible with the DataSource. Check for any inconsistencies or errors in the InfoProvider setup.
- Adjust Selection Criteria: If the DTP has selection criteria, consider relaxing them to see if data can be retrieved. This can help identify if the issue is related to overly restrictive filters.
- Check for Errors in Data Transfer: Look for any error messages or logs related to the data transfer process that might provide additional insights into the issue.
Related Information:
By following these steps, you should be able to identify the root cause of the RSCRT387 error and implement the necessary solutions to resolve it.
Get instant SAP help. Start your 7-day free trial now.
RSCRT386
DTP &1 of DataSource &2 for InfoProvider &3 has no active version
What causes this issue? The data transfer process &V1& from the DataSource &V2& to the InfoProvider &V3& is delivered as DTP ...
RSCRT385
DTP &1 of DataSource &2 for InfoProvider &3 is not assigned
What causes this issue? The data transfer process &V1& from the DataSource &V2& to the InfoProvider &V3& is delivered as DTP ...
RSCRT388
Background job &1 terminates continuously since an hour
What causes this issue? The background job &V1& should execute a daemon for real-time data acquisition (RDA), but it hs been continuously ter...
RSCRT389
Daemon &1 terminated correctly during server shutdown
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.