Do you have any question about this error?
Message type: E = Error
Message class: RSCRT - Near-To-Real-Time Messages
Message number: 386
Message text: DTP &1 of DataSource &2 for InfoProvider &3 has no active version
The data transfer process &V1& from the DataSource &V2& to the
InfoProvider &V3& is delivered as DTP for real-time data acquisition.
However, there is no active version of the data transfer process.
The RDA daemon does not execute the data transfer process &V1&. No data
is loaded by RDA from the DataSource &V2& into the InfoProvider &V3&.
Check if data should be loaded by RDA from the DataSource &V2& into the
InfoProvider &V3&. In this case copy the DTP &V1& from the Content and
activate it.
Error message extract from SAP system. Copyright SAP SE.
RSCRT386
- DTP &1 of DataSource &2 for InfoProvider &3 has no active version ?The SAP error message RSCRT386 indicates that a Data Transfer Process (DTP) for a specific DataSource does not have an active version. This can occur in SAP BW (Business Warehouse) when the DTP is not properly configured or activated.
Cause:
- Inactive DTP Version: The DTP may not have been activated after it was created or modified.
- Missing DTP: The DTP might have been deleted or not created for the specified DataSource.
- Transport Issues: If the DTP was transported from another system, it may not have been activated in the target system.
- Configuration Errors: There may be configuration issues with the DataSource or InfoProvider that prevent the DTP from being activated.
Solution:
Activate the DTP:
- Go to the SAP BW system.
- Navigate to the DTP in question (Transaction Code: RSA1).
- Find the DTP for the specified DataSource and InfoProvider.
- Check if it is inactive and activate it.
Check DTP Versions:
- Ensure that the DTP has an active version. You can do this by checking the DTP properties in the Data Warehousing Workbench.
- If there are multiple versions, ensure that the correct version is active.
Recreate the DTP:
- If the DTP is missing or cannot be activated, consider recreating it.
- Make sure to configure it correctly according to your requirements.
Transport Check:
- If the DTP was transported, check the transport logs for any errors.
- Ensure that all necessary objects were transported and activated in the target system.
Check DataSource and InfoProvider:
- Verify that the DataSource and InfoProvider are correctly configured and active.
- Ensure that there are no issues with the underlying data model that could affect the DTP.
Related Information:
By following these steps, you should be able to resolve the RSCRT386 error and ensure that your DTP is properly configured and active.
Get instant SAP help. Start your 7-day free trial now.
RSCRT385
DTP &1 of DataSource &2 for InfoProvider &3 is not assigned
What causes this issue? The data transfer process &V1& from the DataSource &V2& to the InfoProvider &V3& is delivered as DTP ...
RSCRT384
Could not start repair process chain &1 for &2 (log ID &3)
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
RSCRT387
DTP &1 of DataSource &2 for InfoProvider &3 has no instance
What causes this issue? The data transfer process &V1& from DataSource &V2& to InfoProvider &V3& appears to be faulty. The me...
RSCRT388
Background job &1 terminates continuously since an hour
What causes this issue? The background job &V1& should execute a daemon for real-time data acquisition (RDA), but it hs been continuously ter...
Click on this link to search all SAP messages.