Do you have any question about this error?
Message type: E = Error
Message class: QS - QM: Master data
Message number: 708
Message text: No validity period was selected for inspection method & & &
You want to edit inspection method &v1&, plant &v2&, key date &v3&.
The system cannot select a validity period for the selection criteria
you entered, since:
The inspection method has not been created <ZH>or</>
You do not have authorization to process the inspection method <ZH>or
</>
The inspection method is/was being used and cannot therefore be
deleted.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
QS708
- No validity period was selected for inspection method & & & ?The SAP error message QS708 ("No validity period was selected for inspection method & & &") typically occurs in the context of Quality Management (QM) when you are trying to create or process an inspection lot, and the system cannot find a valid inspection method for the specified material and inspection type.
Cause:
- Missing Validity Period: The inspection method you are trying to use does not have a defined validity period. This means that the system cannot determine if the inspection method is applicable for the material and the inspection type you are working with.
- Incorrect Configuration: The inspection method may not be properly configured in the system, or it may not be assigned to the material or inspection type.
- Material Master Data: The material master data may not have the necessary quality management views or settings configured.
- Inspection Type: The inspection type you are using may not be linked to the inspection method in the system.
Solution:
Check Inspection Method Configuration:
- Go to the transaction code
QMT1
(Create Inspection Method) orQMT2
(Change Inspection Method) to check the configuration of the inspection method.- Ensure that the validity period is correctly defined for the inspection method you are trying to use.
Assign Inspection Method to Material:
- Use transaction code
MM02
to change the material master data.- Navigate to the Quality Management view and ensure that the correct inspection method is assigned to the material for the relevant inspection type.
Review Inspection Type Settings:
- Check the configuration of the inspection type in transaction code
OQ01
(Define Inspection Types) to ensure that it is correctly set up and linked to the inspection method.Check Validity Period:
- Ensure that the current date falls within the validity period of the inspection method. If the validity period has expired, you may need to update it.
Consult Documentation:
- If you are unsure about the configuration, refer to SAP documentation or consult with your SAP QM consultant for guidance on setting up inspection methods and their validity periods.
Related Information:
QMT1
- Create Inspection MethodQMT2
- Change Inspection MethodMM02
- Change Material MasterOQ01
- Define Inspection TypesBy following these steps, you should be able to resolve the QS708 error and ensure that the inspection method is correctly configured and applicable for your materials and inspection types.
Get instant SAP help. Start your 7-day free trial now.
QS707
Inspection & & & has already been created
What causes this issue? INCLUDE Q_VERSION OBJECT DOKU ID TX LANGUAGE DESystem Response The system issues an error message and will not allow you to ...
QS706
Inspection method & & & was deleted
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
QS709
This inspection method is marked for deletion
What causes this issue? This inspection method version is marked for deletion. As a result, you cannot use this method anymore.System Response The s...
QS710
No time line is available for this inspection method
What causes this issue? No validity period has been created for this inspection method, which differs from those already edited. Therefore no time li...
Click on this link to search all SAP messages.