Message type: E = Error
Message class: QP - Message IDs for function module group QPAA
Message number: 621
Message text: Control indicator and tolerance key are not compatible
The control indicators of the characteristic are not compatible with
the tolerance key that was entered.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Cancel the function and check the control indicators of the
characteristic.
Error message extract from SAP system. Copyright SAP SE.
QP621
- Control indicator and tolerance key are not compatible ?The SAP error message QP621, which states "Control indicator and tolerance key are not compatible," typically occurs in the context of Quality Management (QM) when there is a mismatch between the control indicators and tolerance keys defined for a quality inspection characteristic.
Cause:
Incompatible Settings: The control indicator and tolerance key assigned to a characteristic in the inspection plan are not compatible. This can happen if:
- The control indicator is set to a type that does not allow the use of the specified tolerance key.
- The tolerance key is not suitable for the type of inspection characteristic (e.g., if it is a qualitative characteristic).
Configuration Issues: There may be issues in the configuration of the quality management settings in the system, such as incorrect definitions of control indicators or tolerance keys.
Master Data Issues: The master data for the material or inspection plan may not be set up correctly, leading to this incompatibility.
Solution:
Check Control Indicator and Tolerance Key:
- Go to the inspection characteristic in the inspection plan and verify the control indicator and tolerance key settings.
- Ensure that the control indicator is appropriate for the type of inspection characteristic you are using.
Adjust Settings:
- If you find that the control indicator and tolerance key are indeed incompatible, you may need to change one of them to ensure compatibility. This may involve:
- Changing the control indicator to one that is compatible with the selected tolerance key.
- Modifying the tolerance key to one that is suitable for the control indicator.
Review Configuration:
- Check the configuration settings in the Quality Management module to ensure that the control indicators and tolerance keys are defined correctly.
- You may need to consult with your SAP QM configuration team or refer to SAP documentation for guidance on the correct settings.
Master Data Review:
- Review the master data for the material and ensure that all relevant quality management settings are correctly defined.
Testing:
- After making changes, test the inspection plan to ensure that the error no longer occurs.
Related Information:
QP01
(Create Inspection Plan), QP02
(Change Inspection Plan), and QP03
(Display Inspection Plan) to manage inspection plans and characteristics.If the issue persists after following these steps, it may be beneficial to consult with your SAP support team or a consultant who specializes in SAP QM for further assistance.
Get instant SAP help. Start your 7-day free trial now.
QP620
Define the control key profile &
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
QP617
Copying characteristic data from the tolerance key
What causes this issue? You entered a tolerance key in the inspection characteristic.System Response The system reads the specifications from the to...
QP622
Limit values and class definitions were reset
What causes this issue? After you enter the tolerance key, the original data will be overwritten.System Response The system issues an error message ...
QP623
Target value is set to zero (relative tolerances)
What causes this issue? When you use a relative tolerance, the target value must be available.System Response The system issues an error message and...
Click on this link to search all SAP messages.