Do you have any question about this error?
Message type: E = Error
Message class: QD - Message-Id. für Dynamisierung
Message number: 705
Message text: The new inspection stage & is not available
Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of messages in the SAP system have a message text, however this is frequently insufficient to comprehend or resolve the problem.
To make things easier, more detailed information is frequently added to describe the issue, how to fix it, and the necessary steps or configuration modifications.
Unfortunately, there isn't any extra information in this error notice.
First, use our AnswerBot below to get a possible cause and solution (requires a premium subscription).
Also, review the in-depth Common Questions & Answers listed below; you could discover a solution there or be able to connect with others who have faced similar challenges.
You can also try searching the SAP support portal (support.sap.com) but you need a special user ID to access it. It is possible that an SAP support note exists that provides additional details about the mistake or even steps for fixing it.
QD705
- The new inspection stage & is not available ?The SAP error message QD705, which states "The new inspection stage & is not available," typically occurs in the context of Quality Management (QM) when trying to create or process an inspection lot. This error indicates that the system cannot find the specified inspection stage for the inspection lot you are working with.
Causes:
- Missing Inspection Stage: The inspection stage you are trying to use has not been defined in the system.
- Incorrect Configuration: The configuration for the inspection plan may not be set up correctly, leading to the system not recognizing the inspection stage.
- Status of Inspection Plan: The inspection plan might be inactive or not assigned correctly to the material or process.
- Versioning Issues: If there are multiple versions of the inspection plan, the system may be referencing an outdated or incorrect version.
Solutions:
Check Inspection Stage Configuration:
- Go to the inspection plan configuration and verify that the inspection stage you are trying to use is defined and active.
- Use transaction code
QP01
to check the inspection plan and its stages.Review Inspection Plan Assignment:
- Ensure that the inspection plan is correctly assigned to the material and that the relevant characteristics are included.
- Use transaction code
QP02
to modify the inspection plan if necessary.Activate Inspection Plan:
- If the inspection plan is inactive, activate it using transaction code
QP02
orQP03
to ensure it is available for use.Check for Version Conflicts:
- If there are multiple versions of the inspection plan, ensure that the correct version is being referenced in your process.
Consult Documentation:
- Review SAP documentation or help files related to Quality Management for additional insights on managing inspection stages.
Contact SAP Support:
- If the issue persists after checking the above points, consider reaching out to SAP support for further assistance.
Related Information:
QP01
: Create Inspection PlanQP02
: Change Inspection PlanQP03
: Display Inspection PlanBy following these steps, you should be able to identify the cause of the QD705 error and implement the appropriate solution.
Get instant SAP help. Start your 7-day free trial now.
QD704
The current inspection stage is not available
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
QD703
Inspection severity not found- inspection stage is not available
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
QD706
The dynamic modification rule &1 contains only skip stages
What causes this issue? An inspection lot could not be created because: In the material master (in the quality management view of the inspection setu...
QD707
Dynamic modification by characteristic- no operations could be read
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.