Do you have any question about this error?
Message type: E = Error
Message class: PPEFLO - Messages for iPPE Application Object FLO
Message number: 402
Message text: Line explosion: Invalid object type &1 (&2)
Internal error that should not have occurred.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Contact SAP.
Error message extract from SAP system. Copyright SAP SE.
PPEFLO402
- Line explosion: Invalid object type &1 (&2) ?The SAP error message PPEFLO402, which indicates a "Line explosion: Invalid object type &1 (&2)," typically occurs in the context of production planning and execution, particularly when dealing with the explosion of bills of materials (BOMs) or routing information in the SAP system.
Cause:
The error is generally caused by one of the following issues:
Invalid Object Type: The system is trying to process an object type that is not recognized or is not valid in the context of the operation being performed. This could be due to a misconfiguration or an incorrect entry in the BOM or routing.
Missing or Incorrect Data: The object type referenced in the error message may not exist in the database, or there may be missing data related to the object type that is required for the explosion process.
Custom Development Issues: If there are custom enhancements or modifications in the system, they may not be handling certain object types correctly, leading to this error.
Authorization Issues: Sometimes, the user may not have the necessary authorizations to access certain object types, which can lead to this error.
Solution:
To resolve the PPEFLO402 error, you can take the following steps:
Check Object Type: Verify the object type mentioned in the error message. Ensure that it is valid and exists in the system. You can do this by checking the relevant master data (e.g., BOM, routing).
Review BOM and Routing: Ensure that the BOM and routing data are correctly maintained. Look for any inconsistencies or missing entries that could lead to the error.
Check Custom Code: If there are any custom developments or enhancements, review the code to ensure that it correctly handles the object types being processed.
Authorization Check: Ensure that the user has the necessary authorizations to access the object types involved in the process.
Debugging: If the issue persists, consider debugging the process to identify where the error is occurring. This may require the assistance of a technical consultant.
SAP Notes: Check the SAP Support Portal for any relevant SAP Notes that may address this specific error. There may be patches or updates available that resolve known issues.
Consult Documentation: Review the SAP documentation related to production planning and BOM explosion for any additional insights or troubleshooting steps.
Related Information:
By following these steps, you should be able to identify and resolve the cause of the PPEFLO402 error in your SAP system.
Get instant SAP help. Start your 7-day free trial now.
PPEFLO401
Action points &1 (&2) and &3 (&4) are at the same position on the line
What causes this issue? Action point &V1& at &V2& and action point &V3& at &V4& are at exactly the same position in t...
PPEFLO131
The priority for alternative line &1 (&2 &3) still has to be maintained
What causes this issue? No priority has been selected for the alternative line &V1& when assigning to partial line network. However, other al...
PPEFLO403
Line explosion for &1 &2 is not allowed
What causes this issue? &V1& &V2& is an alternative, but it is not a part of line network. Line explosions are allowed only for nodes...
PPEFLO404
Line explosion in execution mode is not allowed for &1 &2
What causes this issue? You wish to explode a line structure with additional data for Logistics Execution. However, such an explosion is not possible...
Click on this link to search all SAP messages.