Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 260
Message text: QCI : Conversion group - reading group relation not maintained for &
The system requires a relation of the conversion group to the reading
group.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Maintain the relation of the conversion group to the reading group:
<DS:TRAN.O588>Link conversion group to reading group</>.
Display/change reading groups: <DS:TRAN.O587>Create/change reading
group</>.
Error message extract from SAP system. Copyright SAP SE.
O3260
- QCI : Conversion group - reading group relation not maintained for & ?The SAP error message O3260 (QCI: Conversion group - reading group relation not maintained for &) typically occurs in the context of Quality Management (QM) and is related to the configuration of conversion groups and reading groups in the system. This error indicates that there is a missing relationship between a conversion group and a reading group in the system configuration.
Cause:
- Missing Configuration: The primary cause of this error is that the system does not have a defined relationship between the specified conversion group and reading group. This can happen if the configuration was not set up correctly or if it was deleted or not maintained properly.
- Incorrect Master Data: The master data for the material or the inspection plan may not have the correct settings for conversion groups and reading groups.
- Data Migration Issues: If data was migrated from another system, there may be inconsistencies or missing entries in the configuration.
Solution:
To resolve the error, you can follow these steps:
Check Configuration:
- Go to the SAP Easy Access screen and navigate to the following path:
SPRO -> Quality Management -> Quality Planning -> Inspection Plans -> Define Conversion Groups
- Ensure that the conversion group you are trying to use is defined and that there is a relationship established with the appropriate reading group.
Maintain Reading Group:
- Similarly, check the reading groups under:
SPRO -> Quality Management -> Quality Planning -> Inspection Plans -> Define Reading Groups
- Ensure that the reading group is correctly defined and linked to the conversion group.
Assign Conversion Group to Material:
- Check the material master data to ensure that the correct conversion group is assigned. You can do this by going to the material master (transaction code MM03) and checking the relevant views.
Inspect Inspection Plans:
- If the error occurs during the execution of an inspection plan, check the inspection plan settings to ensure that the conversion group and reading group are correctly assigned.
Consult Documentation:
- Review SAP documentation or help files related to Quality Management and the specific configuration of conversion and reading groups for additional guidance.
Testing:
- After making the necessary changes, test the process again to ensure that the error is resolved.
Related Information:
If the issue persists after following these steps, it may be beneficial to consult with your SAP support team or a functional consultant specializing in Quality Management for further assistance.
Get instant SAP help. Start your 7-day free trial now.
O3259
Not all fields are relevant for the selected product type
What causes this issue? Fields are made available for entry in the system dependent on the product type you choose. That helps you to know which fiel...
O3258
Time zone of plant & not consistent with time zone of other items
What causes this issue? You have entered an item for which the time zone information differs from the time zone information of other items in a mater...
O3261
QCI : Reading group entry not present
What causes this issue? An entry is missing in the reading group. The parameter is required for the QCI processing.System Response The system issues...
O3262
Heating value classes are not consistent
What causes this issue? The Quantity Conversion Interface (QCI) checks if the following heating value classes are consistent: the base heating value ...
Click on this link to search all SAP messages.