Message type: E = Error
Message class: GR - Report Writer
Message number: 792
Message text: Library &1: Default set &2 does not exist
The &V1& <DS:GLOS.3526BA38AFAB52B9E10000009B38F974>library</> contains
<DS:DE.DSETNR>default set</> &V2&. However, this set either does not
exist, or does not match characteristic &V3&.
Change the library in transaction <DS:TRAN.GR22>GR22</> and enter an
existing default set.
If this error occurs when you import a transport request, check the
library in the source system of the transport.
If the default set exists there and matches characteristic &V3&,
correct the error by transporting the library with its dependent
objects.
If the default set does not exist there, change the library in the
source system of the transport and run another transport.
Error message extract from SAP system. Copyright SAP SE.
GR792
- Library &1: Default set &2 does not exist ?The SAP error message GR792 indicates that a default set specified for a library does not exist. This error typically occurs in the context of SAP's document management system (DMS) or when dealing with classification and library management.
Cause:
The error message "GR792 Library &1: Default set &2 does not exist" can be caused by several factors:
- Missing Default Set: The specified default set (set &2) for the library (library &1) has not been created or has been deleted.
- Incorrect Configuration: The configuration for the library may be incorrect, pointing to a default set that is not valid.
- Transport Issues: If the library and its default set were transported from one system to another (e.g., from development to production), the default set may not have been included in the transport.
- Authorization Issues: The user may not have the necessary authorizations to access the specified default set.
Solution:
To resolve the GR792 error, you can take the following steps:
Check Default Set Configuration:
- Go to the configuration settings for the library in question.
- Verify if the default set specified actually exists. If it does not, you may need to create it.
Create the Default Set:
- If the default set is missing, create a new default set in the library settings.
- Ensure that the new default set is properly configured and activated.
Review Transport Requests:
- If the issue arose after a transport, check the transport request to ensure that the default set was included.
- If it was not included, you may need to transport it again or create it manually in the target system.
Check Authorizations:
- Ensure that the user encountering the error has the necessary authorizations to access the library and its default set.
- Review the user roles and permissions in the SAP system.
Consult Documentation:
- Refer to SAP documentation or help resources for more detailed information on managing libraries and default sets.
Contact SAP Support:
- If the issue persists after checking the above points, consider reaching out to SAP support for further assistance.
Related Information:
OAC0
(for Document Management System settings) or OAC3
(for managing libraries) to access the relevant configuration areas.By following these steps, you should be able to identify and resolve the cause of the GR792 error in your SAP system.
Get instant SAP help. Start your 7-day free trial now.
GR791
MS Excel Link could not be installed (rc = &1, see long text)
What causes this issue? The desktop component "Report Writer: MS Excel Link" could not be installed. The return code (rc) is &V1&. ...
GR790
Output to Excel not possible in multiple selection.
What causes this issue? You are executing a Report Writer report with multiple selection. You chose Excel as your output medium. Output with Excel is...
GR793
Report &1: Library &2 does not exist
What causes this issue? The report &V1& for <DS:GLOS.3526BA38AFAB52B9E10000009B38F974>library </> &V2& was imported. Howe...
GR794
Report &1 &2: Set &3 either does not exist or is not suitable
What causes this issue? Report &V1& for the <DS:GLOS.3526BA38AFAB52B9E10000009B38F974>library </> &V2& uses the &V3&a...
Click on this link to search all SAP messages.