Do you have any question about this error?
Message type: E = Error
Message class: GG - Messages for FI-SL customizing
Message number: 624
Message text: Table & is already known in Special Purpose Ledger
An entry already exists in table T800A for table &V1&. Existing
entries are not replaced.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
If you want to perform a completely new installation, you must delete
this entry.
Error message extract from SAP system. Copyright SAP SE.
GG624
- Table & is already known in Special Purpose Ledger ?The SAP error message GG624 indicates that a table is already known in the Special Purpose Ledger (SPL). This typically occurs when there is an attempt to create or modify a table in the SPL that has already been defined in the system.
Cause:
- Duplicate Table Definition: The error usually arises when you try to create a new table in the Special Purpose Ledger that has the same name or structure as an existing table.
- Configuration Issues: There may be inconsistencies in the configuration settings or definitions in the SPL.
- Transport Issues: If you are transporting configurations from one system to another, it may lead to conflicts if the table already exists in the target system.
Solution:
- Check Existing Tables: Verify the existing tables in the Special Purpose Ledger to see if the table you are trying to create already exists. You can do this by navigating to the SPL configuration and reviewing the defined tables.
- Modify Existing Table: If the table already exists and you need to make changes, consider modifying the existing table instead of creating a new one.
- Delete or Rename: If the existing table is not needed, you may delete it or rename it if possible, and then proceed with creating the new table.
- Review Transport Requests: If this issue arose after a transport, check the transport requests to ensure that there are no conflicts or duplicates being introduced.
- Consult Documentation: Refer to SAP documentation or notes related to Special Purpose Ledger for any specific guidelines or updates that may pertain to your version of SAP.
Related Information:
OBY6
(for Special Purpose Ledger) to access the configuration settings.By following these steps, you should be able to resolve the GG624 error and proceed with your work in the Special Purpose Ledger.
Get instant SAP help. Start your 7-day free trial now.
GG623
Enter a correct reference table for the direct posting
What causes this issue? You have to define a valid reference for the installation of the direct posting component. The specified summary table has t...
GG622
Error in reference table/reference field for data field &
What causes this issue? Value field &V1& in table &V2& requires a reference table and a reference field. The reference table must be...
GG625
The new tables are entered as Special Purpose Ledger tables
What causes this issue? The newly created tables have been entered in the ATAB table T800A as Special Purpose Ledger tables.System Response The syst...
GG626
The master data access definition for table & already exists
What causes this issue? The system issues an error message and will not allow you to continue with this transaction until the error is resolved. Syst...
Click on this link to search all SAP messages.