Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 382
Message text: MR date for move-in reading of device &1 different from activity date
During the technical device installation, the system determined that a
meter reading has already been entered. The meter reading date of meter
reading, &v2&, differs from the transaction date of the technical
installation, &v3&.
As a result, no allocation of previously recorded meter reading results
is possible.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
The following options are available:
Repeat the technical installation and use the meter reading date of the
existing meter reading as the transaction date
Delete the installation meter reading and enter it as of the
transaction date.
Error message extract from SAP system. Copyright SAP SE.
EL382
- MR date for move-in reading of device &1 different from activity date ?The SAP error message EL382 indicates that there is a discrepancy between the meter reading date (move-in reading date) for a device and the activity date in the system. This error typically occurs in the context of utilities management, particularly when dealing with meter readings and customer move-ins.
Cause: The error arises when: The date of the meter reading (move-in reading) does not match the date of the activity (e.g., the date when the customer is officially moved in). The system has strict validation rules that require these dates to align for accurate billing and reporting.
Solution: To resolve the EL382 error, you can take the following steps: Check Dates: Verify the move-in reading date and the activity date in the system. Ensure that they are consistent and reflect the same date. Adjust Dates: If the dates are different, you may need to: Change the move-in reading date to match the activity date. Alternatively, if the activity date is incorrect,
Get instant SAP help. Sign up for our Free Essentials Plan.
EL381
MR reason 08 (technical installation) only possible at device level
What causes this issue? You tried to make a single entry with meter reading reason 08 (technical installation) at customer, contract, or installation...
EL380
Device &1, reg. &2, MR date &3: Estimation not poss.; maintain rate type
What causes this issue? No <DS:DE.TARIFART>rate type</> can be determined in the installation structure of the register. The rate is dete...
EL383
Table TE935 (automatic MR data monitoring) has not been maintained
What causes this issue? Automatic monitoring of meter reading data was cancelled because the control parameters are missing.System Response The syst...
EL384
The period consumption entered for register &1 is too low
What causes this issue? The linear share that is defined in the installation structure by the period and factor, when extrapolated for a year, is gre...
Click on this link to search all SAP messages.