Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 261
Message text: Error reading table internal TEASTS during extrapolation
No valid time slice could be determined in internal table TEASTS for
device &v1&, register &v2&, installation &v3&.
Extrapolation is cancelled.
Please contact your local SAP Support organization.
Error message extract from SAP system. Copyright SAP SE.
EL261
- Error reading table internal TEASTS during extrapolation ?The SAP error message EL261, which states "Error reading table internal TEASTS during extrapolation," typically occurs in the context of the SAP system when there is an issue with reading data from the internal table TEASTS during the extrapolation process. This error can arise in various scenarios, particularly in the context of data processing or reporting. Causes: Data Integrity Issues: There may be inconsistencies or corruption in the data stored in the internal table TEASTS. Configuration Errors: Incorrect configuration settings in the SAP system can lead to issues when trying to read from the internal table. Authorization Issues: The user may not have the necessary permissions to access the data in the internal table. System Performance: If the system is under heavy load, it may lead to timeouts or failures in reading the required data. Program Errors: There could be bugs or errors in the custom code or standard programs that interact with the TEASTS table. Solutions: Check
Get instant SAP help. Sign up for our Free Essentials Plan.
EL260
Fixed validations are always carried out automatically: no entry required
What causes this issue? Inspection points 95, 96, and 97 are fixed inspections. They are always performed automatically, and do not have to be explic...
EL259
Interval validation for final billing cannot be carried out
What causes this issue? No control parameters for meter reading result entry have been set for the combination of company code &v1& and divis...
EL262
Error reading internal table &2 during extrapolation
What causes this issue? The system could not determine a valid time slice for logical register number &V1& in internal table &V2&.Sys...
EL263
Device &1, register &2: no unique MR document determination possible
What causes this issue? During a dependent validation, the meter reading result of a register in a relationship was re-read via the database. The val...
Click on this link to search all SAP messages.