Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 263
Message text: Device &1, register &2: no unique MR document determination possible
During a dependent validation, the meter reading result of a register
in a relationship was re-read via the database. The validation cannot
be carried out because several meter reading documents were selected.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Check the meter reading documents available on this day for
inconsistencies.
Error message extract from SAP system. Copyright SAP SE.
EL263
- Device &1, register &2: no unique MR document determination possible ?The SAP error message EL263 indicates that the system is unable to determine a unique Material Requirement (MR) document for a specific device and register. This typically occurs in the context of device management or when dealing with meter reading documents in SAP IS-U (Industry Solution for Utilities).
Cause: The error can arise due to several reasons: Multiple MR Documents: There may be multiple MR documents associated with the specified device and register, leading to ambiguity in determining which document to use.
Configuration Issues: Incorrect configuration in the device management settings or in the meter reading process can lead to this error. Data Integrity Issues: There may be inconsistencies or missing data in the master data related to the device or register. Timing Issues: If the MR documents are being processed simultaneously or if there are timing issues in the system, it may lead to this error.
Solution: To resolve the EL263 error, you can take the following
Get instant SAP help. Sign up for our Free Essentials Plan.
EL262
Error reading internal table &2 during extrapolation
What causes this issue? The system could not determine a valid time slice for logical register number &V1& in internal table &V2&.Sys...
EL261
Error reading table internal TEASTS during extrapolation
What causes this issue? No valid time slice could be determined in internal table TEASTS for device &v1&, register &v2&, installation...
EL264
Device &1, register &2: Incomplete MRs in dependent validation &3
What causes this issue? The system attempted to read a meter reading document from the database in order to perform a dependent validation. However, ...
EL265
Dependent validation &1: Readings not complete
What causes this issue? The dependent plausibility checks could not be performed yet, because not all the meter readings in the register relationship...
Click on this link to search all SAP messages.