Do you have any question about this error?
Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 262
Message text: Error reading internal table &2 during extrapolation
The system could not determine a valid time slice for logical register
number &V1& in internal table &V2&.
Extrapolation is canceled.
INCLUDE ISU_SAP OBJECT DOKU ID TX
Error message extract from SAP system. Copyright SAP SE.
EL262
- Error reading internal table &2 during extrapolation ?The SAP error message EL262, which states "Error reading internal table &2 during extrapolation," typically occurs in the context of data processing, particularly when dealing with extrapolation in the SAP system. This error indicates that there is an issue with reading data from an internal table that is necessary for the extrapolation process.
Causes:
- Data Integrity Issues: The internal table may not contain the expected data, or there may be inconsistencies in the data that prevent it from being read correctly.
- Memory Issues: The internal table may be too large for the available memory, leading to read errors.
- Programming Errors: There may be a bug in the ABAP code that handles the extrapolation process, causing it to reference an internal table incorrectly.
- Configuration Issues: Incorrect configuration settings related to the extrapolation process may lead to this error.
- Database Issues: Problems with the underlying database, such as locks or corruption, can also lead to issues when trying to read data.
Solutions:
- Check Data Integrity: Verify that the data in the internal table is complete and consistent. You may need to run data validation checks or reports to identify any discrepancies.
- Review ABAP Code: If you have access to the ABAP code, review it for any potential bugs or logical errors that could lead to this issue. Look for any incorrect references to the internal table.
- Increase Memory Allocation: If the internal table is too large, consider increasing the memory allocation for the process or optimizing the data being processed to reduce the size of the internal table.
- Check Configuration Settings: Review the configuration settings related to the extrapolation process to ensure they are set up correctly.
- Database Check: Perform a check on the database for any locks or corruption. You may need to work with your database administrator to resolve any underlying database issues.
- SAP Notes: Check the SAP Support Portal for any relevant SAP Notes that may address this specific error. There may be patches or updates available that resolve known issues.
Related Information:
If the problem persists after trying the above solutions, it may be necessary to escalate the issue to your SAP support team or consult with SAP directly for further assistance.
Get instant SAP help. Start your 7-day free trial now.
EL261
Error reading table internal TEASTS during extrapolation
What causes this issue? No valid time slice could be determined in internal table TEASTS for device &v1&, register &v2&, installation...
EL260
Fixed validations are always carried out automatically: no entry required
What causes this issue? Inspection points 95, 96, and 97 are fixed inspections. They are always performed automatically, and do not have to be explic...
EL263
Device &1, register &2: no unique MR document determination possible
What causes this issue? During a dependent validation, the meter reading result of a register in a relationship was re-read via the database. The val...
EL264
Device &1, register &2: Incomplete MRs in dependent validation &3
What causes this issue? The system attempted to read a meter reading document from the database in order to perform a dependent validation. However, ...