Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 123
Message text: The meter readings selected have different scheduled meter reading dates
You can only correct several results at once if the order creation
dates are the same.
During validation, the previous reading is used during analysis of the
environment of the meter reading result.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Correct your entries.
Error message extract from SAP system. Copyright SAP SE.
EL123
- The meter readings selected have different scheduled meter reading dates ?The SAP error message EL123 indicates that there is a discrepancy in the scheduled meter reading dates for the meter readings you are trying to process. This error typically occurs in the context of utilities management, particularly when dealing with meter readings in SAP IS-U (Industry Solution for Utilities).
Cause: The error arises when you attempt to process multiple meter readings that have different scheduled reading dates. SAP requires that all selected meter readings share the same scheduled reading date to ensure consistency in processing and reporting.
Solution: To resolve the EL123 error, you can take the following steps: Check Scheduled Reading Dates: Review the scheduled meter reading dates for the selected readings. You can do this by navigating to the relevant transaction in SAP (e.g., transaction code EL31 for meter reading documents). Select Readings with the Same Date: If you are processing multiple meter readings, ensure that you only select those that have the same
Get instant SAP help. Sign up for our Free Essentials Plan.
EL122
No period from previous year could be determined during extrapolation
What causes this issue? The indicator BAPERTYP was allocated the value 'X' in the contract. Either none or an insufficient number of meter ...
EL121
Select only implausible meter reading results
What causes this issue? The meter reading result for device &V1& register &V2& is not plausible or has been saved as "not plausi...
EL124
No validation could be determined for device &1 register &2
What causes this issue? The validations allocated to the register are stored in table TE219. However, an appropriate entry could not be found for &am...
EL125
Dev. &1 reg. &2 is not allocated to an installat. on &3. No rate determ.
What causes this issue? The device is not allocated to an installation. Rate determination, and therefore determination of the allocated validations ...
Click on this link to search all SAP messages.