Do you have any question about this error?
Message type: E = Error
Message class: EL - IS-U meter reading data processing
Message number: 124
Message text: No validation could be determined for device &1 register &2
The validations allocated to the register are stored in table TE219.
However, an appropriate entry could not be found for &V3&.
Possible causes:
1. No rate could be determined for the register.
2. There is no entry stored in table TE219 for the determined rate or
there is no '*'-entry.
A validation is only possible for the formal check.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Check rate determination or include entry in table TE219.
Error message extract from SAP system. Copyright SAP SE.
EL124
- No validation could be determined for device &1 register &2 ?The SAP error message EL124, which states "No validation could be determined for device &1 register &2," typically occurs in the context of SAP IS-U (Industry Solution for Utilities) when there is an issue with the validation of a specific register for a device. This error can arise due to several reasons, and understanding the cause is essential for finding a solution.
Causes:
- Missing Validation Rules: The validation rules for the specific device type or register may not be defined in the system.
- Incorrect Configuration: The device or register may not be correctly configured in the system, leading to the inability to determine the appropriate validation.
- Data Inconsistencies: There may be inconsistencies or missing data in the master data related to the device or register.
- Authorization Issues: The user may not have the necessary authorizations to access the validation rules for the specified device and register.
Solutions:
Check Validation Rules:
- Navigate to the configuration settings for device management in SAP IS-U.
- Ensure that the validation rules for the specific device type and register are defined and active.
Review Device Configuration:
- Verify the configuration of the device and its registers in the system.
- Ensure that all necessary fields are filled out correctly and that the device is properly linked to the relevant validation rules.
Data Consistency Check:
- Perform a consistency check on the master data for the device and register.
- Look for any missing or incorrect entries that could lead to the error.
Authorization Check:
- Ensure that the user encountering the error has the necessary authorizations to access the validation rules.
- If needed, consult with your SAP security team to review and adjust user roles and permissions.
Consult Documentation:
- Refer to SAP documentation or notes related to the specific error message for additional insights or updates that may address the issue.
Contact SAP Support:
- If the issue persists after checking the above points, consider reaching out to SAP support for further assistance. Provide them with detailed information about the error, including the device and register involved.
Related Information:
EL31
(for device management) and EL02
(for register management) to help navigate the system.By following these steps, you should be able to identify the cause of the EL124 error and implement a suitable solution.
Get instant SAP help. Start your 7-day free trial now.
EL123
The meter readings selected have different scheduled meter reading dates
What causes this issue? You can only correct several results at once if the order creation dates are the same. During validation, the previous readin...
EL122
No period from previous year could be determined during extrapolation
What causes this issue? The indicator BAPERTYP was allocated the value 'X' in the contract. Either none or an insufficient number of meter ...
EL125
Dev. &1 reg. &2 is not allocated to an installat. on &3. No rate determ.
What causes this issue? The device is not allocated to an installation. Rate determination, and therefore determination of the allocated validations ...
EL126
Error occurred during pressure correction order for device &1
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.