Message type: E = Error
Message class: BIL - General billing
Message number: 027
Message text: Device &1, register &2 without transformer allocation
The consumption on register &v2& for device &v1& is to be assigned to a
power transformer from &v3& to &v4&. However, the system did not find a
power transformer in the corresponding rate step.
The system cancels billing.
Check whether the register has been added to a device allocation of
<DS:DE.E_ZUART>type</> <LB><NP>5 Power Transformer</></><NP> </>.
Check whether the power transformer has been assigned to the correct
rate step in rate determination.
Check the schema structure, in particular the register consumption
update using variant QUANTI34.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
BIL027
- Device &1, register &2 without transformer allocation ?The SAP error message BIL027 indicates that there is a device (meter) and a register that do not have a transformer allocation in the system. This typically occurs in the context of billing and metering in SAP IS-U (Industry Solution for Utilities).
Cause: Missing Transformer Allocation: The device (meter) is expected to have a transformer allocation, but it has not been set up in the system. This can happen if the device is newly created or if the transformer allocation was not properly configured. Incorrect Configuration: The configuration settings for the device or the register may be incorrect or incomplete. Data Migration Issues: If data was migrated from another system, the transformer allocation might not have been transferred correctly.
Solution: Check Device Configuration: Go to the device master record and check if the transformer allocation is set up correctly. You can do this by navigating to the device in the SAP GUI and reviewing the relevant
Get instant SAP help. Sign up for our Free Essentials Plan.
BIL026
Transformer &1 and consumption in inactive period
What causes this issue? The <DS:DE.E_DEVICE_NBR>Device Not Relevant for Billing</> indicator is selected for power transformer &v1&am...
BIL025
Device &1, register &2 is not a reactive or active meter
What causes this issue? The consumption value for device &v1& and register &v2& is required to calculate power transformer losses. Th...
BIL028
Device &1, register &2 is allocated to an inactive transformer
What causes this issue? You tried to allocate a consumption value on register &v2& for device &v1&, which is greater than zero, to a ...
BIL029
Transformer device &1 has the rating &2
What causes this issue? The system found power transformers with a <DS:DE.E_RATING>rating</> of zero.System Response The system issues a...
Click on this link to search all SAP messages.