Message type: E = Error
Message class: BIL - General billing
Message number: 025
Message text: Device &1, register &2 is not a reactive or active meter
The consumption value for device &v1& and register &v2& is required to
calculate power transformer losses. The <DS:DE.BLIWIRK>reactive/active
characteristic</> is taken into account when doing this. The register
has the reactive/active characteristic &v3& instead of the expected
value &v4&.
The system cancels billing.
Check the schema setup.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
BIL025
- Device &1, register &2 is not a reactive or active meter ?The SAP error message BIL025 indicates that the system is unable to process billing for a specific device (meter) because it is not classified as a reactive or active meter. This error typically arises in the context of utilities billing, where meters are used to measure consumption for billing purposes.
Cause: Incorrect Meter Type: The device (meter) in question may not be set up correctly in the system. It might be classified as a non-metering device or an inactive meter.
Configuration Issues: The meter may not have been configured properly in the SAP system, leading to it not being recognized as a valid meter for billing. Data Inconsistencies: There may be inconsistencies in the master data related to the meter, such as missing or incorrect entries in the device master record. Inactive Status: The meter could be marked as inactive or decommissioned in the system.
Solution: Check Meter Configuration: Verify the configuration of the meter in the
Get instant SAP help. Sign up for our Free Essentials Plan.
BIL024
Device &1, register &2: Missing meter reading for transformer allocation
What causes this issue? Device &v1& and register &v2& are allocated to a power transformer ( <DS:DE.E_ZUART>device allocation t...
BIL023
Operand &1 from ERCHV contains overlapping values
What causes this issue? The periods in the ERCHV entries for operand &v1& overlap. This is not permitted since it does not make sense to add ...
BIL026
Transformer &1 and consumption in inactive period
What causes this issue? The <DS:DE.E_DEVICE_NBR>Device Not Relevant for Billing</> indicator is selected for power transformer &v1&am...
BIL027
Device &1, register &2 without transformer allocation
What causes this issue? The consumption on register &v2& for device &v1& is to be assigned to a power transformer from &v3& t...
Click on this link to search all SAP messages.