Do you have any question about this error?
Message type: E = Error
Message class: CLBW_META - For Generating Metadata
Message number: 020
Message text: InfoObjet base/Source &1 non pertinent (tenir compte du texte descriptif)
When creating an InfoSource for classification or configuration data in
the BW system, the key fields of the basic InfoSource that are linked to
key fields of a OLTP basic DataSource are transferred into the
extraction structure. This only occurs if the key fields of this OLTP
basic DataSource have the same names as the key fields of the
classification DataSource.
For example: a classification DataSource in the OLTP system 1CL_OMAT001
has the same key field as its corresponding basis DataSource (MATNR).
This basis DataSource is linked to a base InfoSource from the BW system
via the key field assignment, for example, MATNR <-> 0MATERIAL. In the
extraction structure of the classification InfoSource to be generated,
the key field 0MATERIAL is transferred. The prerequisite for this is
that the basis InfoSource or basis InfoObject that you entered exists in
the BW system and that it is linked with a basis DataSource from the
OLTP system. This basis DataSource has to correspond with the current
classification or configuration DataSource via key fields of the same
name. If these prerequisites are not fulfilled, the system generates a
proposal for the key fields of the extraction structure. The key fields
proposed by the system can be overwritten later, as needed.
Le système émet un message d'erreur et ne vous permettra pas de poursuivre cette transaction tant que l'erreur n'est pas résolue.
The basic InfoSource or basic InfoObject &V1& that you specified is
linked with a basic DataSource from the OLTP system that does not
correspond with the current DataSource &V2& from the source system. For
this reasons, the program cannot transfer key fields from the structure
of the basic InfoSource. Please check your entries and enter the correct
basic InfoSource, as needed. You can also ignore the message and
continue with the transaction. In this case, the system will generate
the proposals for the key fields that you can overwrite later as needed.
Extrait du message d'erreur du système SAP. Copyright SAP SE.
CLBW_META020
- InfoObjet base/Source &1 non pertinent (tenir compte du texte descriptif) ?Get instant SAP help. Start your 7-day free trial now.
CLBW_META019
Aucune entrée ds zone "InfoObj.base/Source" (tenir compte texte descr.)
Quelle est la cause de ce problème? When creating an InfoSource for classification or configuration data in the BW system, the key fields of the ba...
CLBW_META018
InfoObj/Source & ne possède auc. struct. transf.(tenir cpte texte descr.)
Quelle est la cause de ce problème? When creating an InfoSource for classification or configuration data in the BW system, the key fields of the ba...
CLBW_META021
InfoObjet &1 inexistant (tenir compte du texte descriptif)
Quelle est la cause de ce problème? For this reason, mapping cannot take place between the key field &V2& of the DataSource &V3& a...
CLBW_META022
InfoObjet/Source &1 non pertinent (tenir compte du texte descriptif)
Quelle est la cause de ce problème? An InfoSource in the BW system that is supplied with master data from an OLTP DataSource has a link between an ...
Cliquez sur ce lien pour rechercher tous les messages SAP.