When creating an InfoSource for classification or configuration data in
the BW system, the key fields of the basic InfoSource that are linked to
key fields of a OLTP basic DataSource are transferred into the
extraction structure. This only occurs if the key fields of this OLTP
basic DataSource have the same names as the key fields of the
classification DataSource. Klassifizierung-DataSource sind.
For example: a classification DataSource in the OLTP system 1CL_OMAT001
has the same key field as its corresponding basic DataSource (MATNR).
This base DataSource is linked to a basic InfoSource from the BW system
via the key field assignment, for example, MATNR <-> 0MATERIAL. In the
extraction structure of the classification InfoSource to be generated,
the key field 0MATERIAL is transferred. The prerequisite for this is
that the basis InfoSource or basis InfoObject that you entered exists in
the BW system and that it is linked with a basis DataSource from the
OLTP system. This basic DataSource has to correspond with the current
classification or configuration DataSource via key fields of the same
name. If these prerequisites are not fulfilled, the system generates a
proposal for the key fields of the extraction structure. The key fields
proposed by the system can be overwritten later, as needed.
Le système émet un message d'erreur et ne vous permettra pas de poursuivre cette transaction tant que l'erreur n'est pas résolue.
The basic InfoSource &V1& you specified does not have a link (transfer
structure) to a basic DataSource from the OLTP system. For this reasons,
the program cannot transfer key fields from the structure of the basic
InfoSource. Check your entries and enter the correct basic InfoSource as
needed. You
can also ignore the message and continue with the transaction. In this
case, the system generates the proposals for the key fields, which you
can overwrite later as needed.
Extrait du message d'erreur du système SAP. Copyright SAP SE.
CLBW_META018
- InfoObj/Source & ne possède auc. struct. transf.(tenir cpte texte descr.) ?Get instant SAP help. Start your 7-day free trial now.
CLBW_META017
Nombre maximal d'attributs dépassé (tenir compte du texte descriptif)
Quelle est la cause de ce problème? You want to extend an InfoSource. This will then have more than 255 attributes.Réponse du système There is n...
CLBW_META016
Le DataSource est déjà affecté
Message auto-explicatif Étant donné que SAP estime que ce message d'erreur spécifique est 'auto-explicatif', aucune autre information n'a été fou...
CLBW_META019
Aucune entrée ds zone "InfoObj.base/Source" (tenir compte texte descr.)
Quelle est la cause de ce problème? When creating an InfoSource for classification or configuration data in the BW system, the key fields of the ba...
CLBW_META020
InfoObjet base/Source &1 non pertinent (tenir compte du texte descriptif)
Quelle est la cause de ce problème? When creating an InfoSource for classification or configuration data in the BW system, the key fields of the ba...
Cliquez sur ce lien pour rechercher tous les messages SAP.