Do you have any question about this error?
Message type: E = Error
Message class: CLBW_META - For Generating Metadata
Message number: 019
Message text: Aucune entrée ds zone "InfoObj.base/Source" (tenir compte texte descr.)
When creating an InfoSource for classification or configuration data in
the BW system, the key fields of the basic InfoSource that are linked to
key fields of a OLTP basic DataSource are transferred into the
extraction structure. This only occurs if the key fields of this OLTP
basic DataSource have the same names as the key fields of the cl
assification DataSource.
For example: a classification DataSource in the OLTP system 1CL_OMAT001
has the same key field as its corresponding basic DataSource (MATNR).
This basic DataSource is linked to a basic InfoSource from the BW system
via the key field assignment, for example, MATNR <-> 0MATERIAL. In the
extraction structure of the classification InfoSource to be generated,
the key field 0MATERIAL is transferred. The prerequisite for this is
that the basic InfoSource or basic InfoObject that you entered exists in
the BW system and that it is linked with a basic DataSource from the
OLTP system. This basic DataSource has to correspond with the current
classification or configuration DataSource via key fields of the same
name. If these prerequisites are not fulfilled, the system generates a
proposal for the key fields of the extraction structure. The key fields
proposed by the system can be overwritten later, as needed.
Le système émet un message d'erreur et ne vous permettra pas de poursuivre cette transaction tant que l'erreur n'est pas résolue.
You have not filled in the field "Basic InfoObject/Source" . For this
reason, the system cannot transfer key fields from the structure of the
basic InfoSource (transaction data) or the basic InfoObject (master
data. Please fill in the field. You can also ignore the message and
continue with the transaction. In this case, the system generates
proposals for the key fields that you can then overwrite as needed.
Extrait du message d'erreur du système SAP. Copyright SAP SE.
CLBW_META019
- Aucune entrée ds zone "InfoObj.base/Source" (tenir compte texte descr.) ?Get instant SAP help. Start your 7-day free trial now.
CLBW_META018
InfoObj/Source & ne possède auc. struct. transf.(tenir cpte texte descr.)
Quelle est la cause de ce problème? When creating an InfoSource for classification or configuration data in the BW system, the key fields of the ba...
CLBW_META017
Nombre maximal d'attributs dépassé (tenir compte du texte descriptif)
Quelle est la cause de ce problème? You want to extend an InfoSource. This will then have more than 255 attributes.Réponse du système There is n...
CLBW_META020
InfoObjet base/Source &1 non pertinent (tenir compte du texte descriptif)
Quelle est la cause de ce problème? When creating an InfoSource for classification or configuration data in the BW system, the key fields of the ba...
CLBW_META021
InfoObjet &1 inexistant (tenir compte du texte descriptif)
Quelle est la cause de ce problème? For this reason, mapping cannot take place between the key field &V2& of the DataSource &V3& a...
Cliquez sur ce lien pour rechercher tous les messages SAP.