Do you have any question about this error?
Stop googling SAP errors. Use our Free Essentials plan instead - no credit card needed. Start Now →
Message type: E = Error
Message class: UCFE - Messages for Data Entry Layouts
Message number: 258
Message text: The values of &1 and &2 are not compatible with the layout definition
A selection across multiple characteristics is defined in the relevant
structure of the layout definition. However, the selection of the cell
does not coincide with the "cross-characteristic" selection.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
UCFE258
- The values of &1 and &2 are not compatible with the layout definition ?The SAP error message UCFE258 indicates that there is a compatibility issue between the values being processed and the layout definition in a report or data structure. This typically occurs in the context of SAP's reporting tools, such as SAP Query or SAP Report Painter, where the layout definition specifies how data should be displayed or formatted.
Cause:
- Data Type Mismatch: The values being passed do not match the expected data types defined in the layout. For example, if the layout expects a numeric value but receives a character string, this error can occur.
- Field Length Issues: The length of the data being processed may exceed the defined length in the layout. For instance, if a field is defined to hold 10 characters but the data being passed is 15 characters long.
- Incompatible Formats: The format of the data (e.g., date formats, currency formats) may not align with what the layout expects.
- Incorrect Field Mapping: The fields in the data source may not be correctly mapped to the fields in the layout definition.
Solution:
- Check Data Types: Review the data types of the fields being used in the report and ensure they match the expected types in the layout definition.
- Adjust Field Lengths: Ensure that the lengths of the data being processed do not exceed the defined lengths in the layout. If necessary, modify the layout definition to accommodate longer values.
- Verify Formats: Check the formats of the data being passed and ensure they are compatible with the layout definition. For example, ensure date formats are consistent.
- Review Field Mapping: Go through the field mapping in the report or query to ensure that all fields are correctly aligned with the layout definition.
- Test with Sample Data: If possible, test the report with sample data that is known to be compatible with the layout to isolate the issue.
Related Information:
By following these steps, you should be able to identify and resolve the issue causing the UCFE258 error message in SAP.
Get instant SAP help. Sign up for our Free Essentials Plan.
UCFE257
&1 &2 is not contained in the maximum selection
What causes this issue? A maximum selection with the value &V2& is defined for characteristic &V1& for the <DS:GLOS.FF560191A481D5...
UCFE256
Item &1 has a breakdown by &2, but default &3 of &2 is not allowed
What causes this issue? Item &V1& has a breakdown by characteristic &V2&. However, the default value &V3& of characteristic &...
UCFE259
Conflict in definition of the predefined fixed structures
What causes this issue? The selection subset for this cell is empty due to a conflict in the predefined fixed structure in the selection for the rele...
UCFE260
Item &1 requires breakdowns by &2, but &2 is missing in the layout
What causes this issue? Item &V1& requires a breakdown by characteristic &V2&. However, characteristic &V2& is missing in the...
Click on this link to search all SAP messages.