How To Fix REXCJP336 - End reading missing for meter & assigned to & for period &


SAP Error Message - Details

  • Message type: E = Error

  • Message class: REXCJP - Localization Flexible Real Estate Japan

  • Message number: 336

  • Message text: End reading missing for meter & assigned to & for period &

  • Show details Hide details
  • What causes this issue?

    End meter reading missing for the selected meter and period.

    System Response

    The system issues an error message and will not allow you to continue with this transaction until the error is resolved.

    How to fix this error?

    Interpretation of the measurement documents for the service charge
    settlement with fix unit prices in Japan:
    The first measurement document defined for a day shows the final meter
    reading on the day before the date of the measurement document.
    Additional measurement documents defined for a day show the meter
    readings on the day of the measurement documents.
    Exapmple:
    For a meter, there are the following measurement documents:
    31.12.2005,, 0,000,,kWh,,( shows the consumption till 30.12.2005 )
    31.01.2006,,1000,000,,kWh,,( shows the consumption between 31.12.2005 -
    30.01.2006 )
    28.02.2006,,1000,000,,kWh,,( shows the consumption between 31.01.2006 -
    27.02.2006 )
    For the period, 01.01.2006 - 31.01.2006 the consumption will be in this
    case: 1003 kWh.
    ( 30 day * 1000 kWh / 31 day + 1 day * 1000 kWh / 28 day = 1003 kWh )

    Procedure for System Administrators


    Error message extract from SAP system. Copyright SAP SE.


Smart SAP Assistant

  • What is the cause and solution for SAP error message REXCJP336 - End reading missing for meter & assigned to & for period & ?

    The SAP error message REXCJP336 typically indicates that there is a missing end reading for a meter that is assigned to a specific object (like a contract or a location) for a given period. This error is often encountered in the context of SAP IS-U (Industry Solution for Utilities) when dealing with meter readings and billing processes.

    Cause:

    1. Missing End Reading: The primary cause of this error is that the system expects an end meter reading for a specific period, but it cannot find one. This can happen if:

      • The end reading was not recorded.
      • The end reading was recorded incorrectly.
      • The reading was deleted or not saved properly.
    2. Incorrect Configuration: There may be configuration issues in the meter reading process or in the assignment of meters to contracts.

    3. Data Entry Errors: Manual data entry errors can lead to missing or incorrect readings.

    Solution:

    1. Check Meter Readings:

      • Go to the relevant transaction (e.g., transaction code EL31 for meter reading documents) and check if the end reading for the specified meter and period exists.
      • If it is missing, you will need to enter the end reading manually.
    2. Review Meter Assignment:

      • Ensure that the meter is correctly assigned to the relevant contract or location. You can check this in the master data for the meter.
    3. Correct Configuration:

      • If there are configuration issues, consult with your SAP IS-U configuration team to ensure that the meter reading process is set up correctly.
    4. Reprocess Meter Reading:

      • If the meter reading was processed incorrectly, you may need to reverse the reading and re-enter it.
    5. Consult Documentation:

      • Review SAP documentation or notes related to this error message for any specific guidance or patches that may address the issue.

    Related Information:

    • Transaction Codes: Familiarize yourself with relevant transaction codes such as EL31 (for meter reading documents), EL22 (for meter reading results), and EL24 (for meter reading history).
    • SAP Notes: Check SAP Notes for any known issues or updates related to this error message.
    • User Roles: Ensure that the user has the necessary permissions to enter or modify meter readings.
    • Training: If this is a recurring issue, consider providing additional training for users involved in the meter reading process to minimize data entry errors.

    By following these steps, you should be able to resolve the REXCJP336 error and ensure that all necessary meter readings are recorded correctly.

    • Do you have any question about this error?


      Upgrade now to chat with this error.


Instant HelpGet instant SAP help. Sign up for our Free Essentials Plan.


Related SAP Error Messages

Click the links below to see the following related messages:

Click on this link to search all SAP messages.


Rating
ERPlingo simplifies finding the accurate answers to SAP message errors. I now use every week. A must have tool for anyone working with SAP! Highly recommended!
Rate 1
Kent Bettisworth
Executive SAP Consultant