Do you have any question about this error?
Message type: E = Error
Message class: QS - QM: Master data
Message number: 082
Message text: You cannot use master inspection char. as "incomplete copy model"
You want to use a master inspection characteristic that has been
changed without history as an incomplete copy model. This is not
possible because the master inspection characteristic is being used:
As a reference in a task list
In a material specification
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Choose one of the following options:
Define the master inspection characteristic either as a reference
characteristic or a complete copy model.
Cancel the references to the master inspection characteristic in the
task lists or material specifications.
The uses can be displayed with the aid of the where-used list.
Change the master inspection characteristic <ZH>with </> history.
Error message extract from SAP system. Copyright SAP SE.
QS082
- You cannot use master inspection char. as "incomplete copy model" ?The SAP error message QS082 indicates that you are trying to use a master inspection characteristic (MIC) as an "incomplete copy model" in a Quality Management (QM) context, which is not allowed. This typically occurs when you are attempting to copy or create a new inspection plan or characteristic based on an existing one, but the system has identified that the selected MIC is not suitable for this operation.
Cause:
- Master Inspection Characteristic Type: The MIC you are trying to use may not be defined correctly or is not set up to be used as a copy model. This can happen if the MIC is marked as "incomplete" or if it has certain attributes that prevent it from being used in this way.
- Configuration Issues: There may be configuration settings in the Quality Management module that restrict the use of certain MICs for copying purposes.
- Data Integrity: The MIC might be missing required data or settings that are necessary for it to be used as a model.
Solution:
- Check MIC Configuration: Review the configuration of the master inspection characteristic in the system. Ensure that it is complete and correctly set up for use as a copy model. You can do this by navigating to the relevant transaction (e.g., QS21 for MIC maintenance) and checking the details of the MIC.
- Use a Different MIC: If the current MIC cannot be used, consider selecting a different MIC that is properly configured and marked as complete.
- Review Inspection Plan Settings: If you are working with an inspection plan, ensure that the plan and its characteristics are correctly defined and that there are no inconsistencies.
- Consult Documentation: Refer to SAP documentation or help resources for specific guidelines on using MICs and creating inspection plans.
- Contact SAP Support: If you are unable to resolve the issue, consider reaching out to SAP support or your internal SAP team for further assistance.
Related Information:
By following these steps, you should be able to identify the cause of the QS082 error and implement a suitable solution.
Get instant SAP help. Start your 7-day free trial now.
QS081
The class char. and the master inspection char. are not compatible
What causes this issue? You want to assign a class characteristic to the master inspection characteristic after the master inspection characteristic ...
QS080
Data is preassigned in the master inspection characteristic
What causes this issue? You want to create a link to a class characteristic. To do this, certain data has to be changed in the master inspection char...
QS083
Enter the tolerance key
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
QS084
You can only change certain control indicators
What causes this issue? You want to change a master inspection characteristic. Certain control indicators cannot be changed. Others can only be chang...
Click on this link to search all SAP messages.