How To Fix PYC_FRW366 - HAS-TO-BE-FIXED input type parameter &1 not found for check instance &2


PYC_FRW366 - Overview

  • Message type: E = Error

  • Message class: PYC_FRW - Payroll Control Center Framework

  • Message number: 366

  • Message text: HAS-TO-BE-FIXED input type parameter &1 not found for check instance &2

  • Show details Hide details
  • What causes this issue?

    The data source type for the check instance has been assigned input
    parameter &V1&. This input parameter is marked as "requiring fixed value
    at configuration time" (PYD_TYPTI_FIXED_IND field) in the Customizing
    activity <DS:SIMG.PYD_FRW_1>Define Data Source Types</>.
    However, this same input parameter has not been assigned to the check
    instance (of this data source type).

    System Response

    The system reads the input parameter attributes of the data source type
    of the data source instance.
    The system finds that an input parameter type is marked as Fixed
    (meaning requiring a fixed value at configuration time).
    The system looks for the same input parameter for the data source
    instance in the Customizing activity
    <DS:SIMG.PYD_FRW_3>Define Data Source Instances</>.
    The system does not find the input parameter type assigned to the data
    source instance and then throws this message.

    How to fix this error?

    RESET N1
    In the Customizing activity
    <DS:SIMG.PYD_FRW_3>Define Data Source Instances</>, note down the data
    source type for the data source instance.
    In the Customizing activity
    <DS:SIMG.PYD_FRW_1>Define Data Source Types</> <LS>-> Define Data
    Source Types</>, find out for the data source type which input
    parameters are marked as Fixed and Mandatory.
    In the Customizing activity
    <DS:SIMG.PYD_FRW_3>Define Data Source Instances</>, add the same input
    parameters of Step 2 to the data source instance and specify the
    Selection Value for these parameters.

    Procedure for System Administrators

    The system issues an error message and will not allow you to continue with this transaction until the error is resolved.


    Error message extract from SAP system. Copyright SAP SE.


Smart SAP Assistant

  • What is the cause and solution for SAP error message PYC_FRW366 - HAS-TO-BE-FIXED input type parameter &1 not found for check instance &2 ?
    The SAP error message PYC_FRW366 indicates that there is an issue with a specific input type parameter that is not found for a check instance in the context of SAP Profitability and Performance Management (PaPM) or SAP Financial Planning.
    
    Cause: The error typically arises due to one of the following reasons: Missing Input Type Parameter: The specified input type parameter (&1) is not defined or is incorrectly configured in the system. Incorrect Check Instance: The check instance (&2) may not be properly set up or may not correspond to the expected input type parameters.
    Configuration Issues: There may be issues in the configuration of the check instance or the associated input types, leading to the system being unable to find the required parameters.
    Solution: To resolve the error, you can follow these steps: Verify Input Type Parameters: Check the configuration of the input type parameters in the relevant check instance. Ensure that the parameter specified in the error message

    Already have an account? Login here!




Instant HelpGet instant SAP help. Sign up for our Free Essentials Plan.


Related SAP Error Messages

Click the links below to see the following related messages:

Click on this link to search all SAP messages.


Rating
ERPlingo's SAP support assistant is amazing. Saves me countless hours trying to solve complex SAP issues myself. It's a real game changer!
Rate 1
Thomas Michael
SAP Consultant, Author & Speaker