Message type: E = Error
Message class: OIUME - Measurement messages
Message number: 023
Message text: Derived reading & not provided by calculation &.
The measurement system is configured to perform one or more calculations
on the measurement readings you have entered.
However, the configuration in inconsistent. The calculation &v2&
provides the derived reading &v1& as output, but this reading is not
recognized by the measurement you are trying to carry out.
The measurement transaction is cancelled.
Contact your system administrator.
Either:
Amend the measurement type &v3& to include the observed reading &v1&
ENDIF
or
Remove the reading &v1& from the calculation &v2&
ENDIF
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
The SAP error message OIUME023, which states "Derived reading & not provided by calculation &," typically occurs in the context of SAP IS-U (Industry Solution for Utilities) when dealing with meter readings and derived readings. This error indicates that the system is expecting a derived reading to be calculated based on existing data, but it has not been provided or is missing.
Cause: Missing Calculation Logic: The system may not have the necessary logic or configuration to derive the reading based on the available data. Data Inconsistency: There may be inconsistencies or missing data in the meter reading records that prevent the system from calculating the derived reading.
Configuration Issues: The configuration settings for the meter reading process may not be set up correctly, leading to the inability to derive readings. Incorrect Meter Reading Type: The type of meter reading being processed may not be compatible with the derived reading calculation.
Solution: Check Configuration: Review the configuration
Get instant SAP help. Sign up for our Free Essentials Plan.
OIUME022
Derived reading & is missing for calculation &.
What causes this issue? The measurement system is configured to perform one or more calculations on the measurement readings you have entered. Howeve...
OIUME021
Observed reading & is missing for calculation &.
What causes this issue? The PRA Measurement System is configured to carry out one or more calculations on the measurement readings you have entered. ...
OIUME024
No characteristics found for reading type &, UoM Grp &.
What causes this issue? All readings in a measurement are assigned to a reading type, which defines characteristics for the reading such as: Format (...
OIUME025
Number range missing or invalid for measurement type &.
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
Click on this link to search all SAP messages.