Message type: E = Error
Message class: OIUME - Measurement messages
Message number: 022
Message text: Derived reading & is missing for calculation &.
The measurement system is configured to perform one or more calculations
on the measurement readings you have entered.
However, the configuration is inconsistent. The current measurement
requires the derived reading &v1&, but this reading is not provided by
calculation routine &v2&.
The measurement transaction is cancelled.
Contact your system administrator.
Either:
Amend the measurement type &v3& to include the observed reading &v1&
ENDIF
or
remove the reading &v1& from the calculation &v2&
ENDIF
Error message extract from SAP system. Copyright SAP SE.
The SAP error message OIUME022 indicates that a derived reading is missing for a calculation in the context of the SAP IS-U (Industry Solution for Utilities) module. This error typically occurs when the system is trying to perform a calculation based on readings (like meter readings) but cannot find the necessary derived reading that it expects.
Cause: Missing Derived Reading: The primary cause of this error is that the system is unable to find a derived reading that is required for the calculation. This could be due to: The derived reading not being created or saved in the system. Incorrect configuration or settings in the reading type or calculation type. Data inconsistencies or missing entries in the database. Incorrect Configuration: The configuration settings for the reading types or calculation types may not be set up correctly, leading to the system not being able to derive the necessary readings. Data Issues: There may be issues with the data
Get instant SAP help. Sign up for our Free Essentials Plan.
OIUME021
Observed reading & is missing for calculation &.
What causes this issue? The PRA Measurement System is configured to carry out one or more calculations on the measurement readings you have entered. ...
OIUME020
Enter number in correct format: &
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
OIUME023
Derived reading & not provided by calculation &.
What causes this issue? The measurement system is configured to perform one or more calculations on the measurement readings you have entered. Howeve...
OIUME024
No characteristics found for reading type &, UoM Grp &.
What causes this issue? All readings in a measurement are assigned to a reading type, which defines characteristics for the reading such as: Format (...