Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 357
Message text: UOM '&' not found in appendix table (material & plant &)
Before the system posts a material document for a Hydrocarbon Inventory
Management material, it performs the following consistency checks:
For each unit of measure in the Unit of Measure Group, a line item has
to be present in the appendix table (Table MSEGO2)
For each unit of measure in table MSEG that is not initial, a line item
has to be present in the appendix table (Table MSEGO2) and the
corresponding quantities have to be identical.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
This way, inconsistent stock level updates can be prevented.The system stops processing.
If the error is reproducible, contact your system administrator.
The inconsitency can have several reasons, for example:
Incorrect postings from external systems using function module
MB_CREATE_GOODS_MOVEMENT
Handling errors
Application programming errors
Error message extract from SAP system. Copyright SAP SE.
O3357
- UOM '&' not found in appendix table (material & plant &) ?The SAP error message O3357 indicates that the Unit of Measure (UOM) specified in the system is not found in the appendix table for the given material and plant. This typically occurs when you are trying to perform an operation that involves a specific UOM that has not been defined or is not valid for the material in question.
Cause: Missing UOM Definition: The UOM you are trying to use has not been defined in the system for the specified material and plant. Incorrect UOM: The UOM might be incorrectly entered or does not exist in the UOM table. Material Master Data Issues: The material master data may not have the necessary UOM settings configured properly. Plant-Specific Settings: The UOM may not be valid for the specific plant you are working with.
Solution: Check UOM Configuration: Go to the transaction code CUNI (Unit of Measure Conversion) to check if the UOM is defined in the system. Ensure that the
Get instant SAP help. Sign up for our Free Essentials Plan.
O3356
Line & (OIL-material &): Additional quantity table is empty
What causes this issue? Before the system posts a material document for a Hydrocarbon Product Management material, it performs the following consiste...
O3354
Transaction data is only available in test mode
What causes this issue? In Customizing, the new default parameter transaction is activated in test mode only. There you select whether the QCI uses t...
O3359
Material & / & Column &: MSEG-& not in quantity table/not consistent
What causes this issue? Before the system posts a material document for an HPM/TDP material (MARA-CMETH = 1 or 2), it performs the following consiste...
O3361
Transaction unit of measure for BSW % has to be at ambient conditions
What causes this issue? The Quantity Conversion Interface (QCI) allows you to calculate target quantities that are corrected for BSW content (Volume ...
Click on this link to search all SAP messages.