Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 316
Message text: Test or material temperature and unit for test density are not specified
The test or material temperature and unit of measure are both not
specified. The Quantity Conversion Interface (QCI) will pass a
temperature value of 0 to the external functions (API c-code, customer
function). Without a unit of measure, this may lead to an incorrect
result.
This message can be customized to appear as an error, warning or
information message (Transaction O591). SAP recommends that this message
is set as an error message, but you might want to pass an unspecified
test temperature value to your own routines.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
O3316
- Test or material temperature and unit for test density are not specified ?The SAP error message O3316 indicates that there is an issue with the configuration of a test or material in the system, specifically related to the temperature and unit for test density not being specified. This error typically arises in the context of quality management (QM) within SAP, where specific parameters must be defined for materials and their associated tests.
Cause: Missing Configuration: The test or material does not have the required temperature and unit for test density specified in the system. Incomplete Master Data: The material master or the quality inspection characteristics may not be fully configured. Incorrect Settings: The settings in the quality management module may not align with the requirements for the specific material or test.
Solution: To resolve the O3316 error, follow these steps: Check Material Master Data: Go to the material master record (transaction code MM02). Ensure that the relevant quality management views are maintained. Specifically, check the "Quality Management" view for the material and
Get instant SAP help. Sign up for our Free Essentials Plan.
O3315
Target unit of measure parameters not specified
What causes this issue? The Quantity Conversion Interface (QCI) requires temperature and pressure specifications for all target units of measure. For...
O3314
Conversion parameters taken from first available reason code
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
O3317
Material temperature or target volume reference temperature out of range
What causes this issue? You have either entered a material temperature value that lies outside the recommended range specified in ISO 13443:1996(E), ...
O3318
Material pressure or target volume reference pressure out of range
What causes this issue? You have either entered a material pressure value that lies outside the recommended range specified in ISO 13443:1996(E) or t...
Click on this link to search all SAP messages.