Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 315
Message text: Target unit of measure parameters not specified
The Quantity Conversion Interface (QCI) requires temperature and
pressure specifications for all target units of measure. For liquid
products, the temperature specification is usually sufficient; for
natural gas both pressure and temperature value is required. If the
target unit of measure has no values specified in Customizing, the
material temperature and pressure are used. If these values are also not
specified, the conversion cannot be performed.
The conversion process will not continue.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
O3315
- Target unit of measure parameters not specified ?The SAP error message O3315, "Target unit of measure parameters not specified," typically occurs in the context of material management or inventory management when there is an issue with the unit of measure (UoM) settings for a material or during a transaction that involves unit conversions.
Cause: Missing UoM Configuration: The target unit of measure for a material may not be defined in the material master data. Incorrect UoM Settings: The conversion factors between different units of measure may not be set up correctly. Transaction Context: The error can occur during specific transactions, such as goods movements, where the system expects a target unit of measure to be specified but it is not.
Solution: Check Material Master Data: Go to the material master record (transaction code MM03). Check the "Basic Data" and "Purchasing" views to ensure that the target unit of measure is defined. Ensure that the "Alternative Units of Measure" section is filled out correctly, including the conversion
Get instant SAP help. Sign up for our Free Essentials Plan.
O3314
Conversion parameters taken from first available reason code
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
O3313
Unit of measure & not customized
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
O3316
Test or material temperature and unit for test density are not specified
What causes this issue? The test or material temperature and unit of measure are both not specified. The Quantity Conversion Interface (QCI) will pas...
O3317
Material temperature or target volume reference temperature out of range
What causes this issue? You have either entered a material temperature value that lies outside the recommended range specified in ISO 13443:1996(E), ...