Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 304
Message text: Combustion temperature value for target energy is 0; no UoM specified
A temperature value of zero is passed to the Quantity Conversion
Interface (QCI) for a combustion reference temperature of an energy
unit of measure. No unit of measure for the combustion reference
temperature is passed to the QCI. The system will calculate the target
energy quantity at the base combustion temperature defined in the
conversion group.
The system will continue processing if the message is customized to
appear as a warning or information message.
Check the results of the quantity conversion. This message can be
customized to appear as an error, warning or information message, or not
to appear at all (Transaction O591).
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
O3304
- Combustion temperature value for target energy is 0; no UoM specified ?The SAP error message O3304, which states "Combustion temperature value for target energy is 0; no UoM specified," typically occurs in the context of energy management or production planning within SAP, particularly when dealing with target energy values for combustion processes.
Cause: Zero Value for Combustion Temperature: The error indicates that the system is trying to process a combustion temperature value that is set to zero. This could happen if the data entry for the combustion temperature was not completed or was incorrectly set. Missing Unit of Measure (UoM): The error also suggests that there is no unit of measure specified for the combustion temperature. This is critical because the system needs to know how to interpret the temperature value (e.g., Celsius, Fahrenheit).
Solution: Check and Update Combustion Temperature: Navigate to the relevant transaction or configuration where the combustion temperature is defined. Ensure that a valid, non-zero combustion temperature value is entered. Specify Unit of Measure: Ensure that a
Get instant SAP help. Sign up for our Free Essentials Plan.
O3303
The number & is not in the correct format
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
O3302
AGA8:Warning code 49: Sum of mole fractions within a warning range
What causes this issue? The sum of the mole fractions is larger than 1.0001 or smaller than 0.9999. The AGA c-code can still calculate the compressio...
O3305
Thermal expansion coefficient can not be zero for product type 'chemical'
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
O3306
Natural gas test density is zero; enter a test density
What causes this issue? The test density/relative test density of the natural gas product is zero.How to fix this error? Enter a valid density/rel...