Do you have any question about this error?
Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 302
Message text: AGA8:Warning code 49: Sum of mole fractions within a warning range
The sum of the mole fractions is larger than 1.0001 or smaller than
0.9999. The AGA c-code can still calculate the compression factor.
The QCI (Quantity Conversion Interface) continues processing
Check the sum of the mole fractions.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
O3302
- AGA8:Warning code 49: Sum of mole fractions within a warning range ?The SAP error message O3302 AGA8: Warning code 49: "Sum of mole fractions within a warning range" typically occurs in the context of process engineering or chemical calculations within SAP, particularly when dealing with gas mixtures and their properties.
Cause:
This warning indicates that the sum of the mole fractions of the components in a gas mixture does not equal 1.0, but is within a specified warning range. This can happen due to:
- Data Entry Errors: Incorrect input values for the mole fractions of the components.
- Component Definitions: Incomplete or incorrect definitions of the components in the mixture.
- Calculation Rounding: Rounding errors in calculations that lead to a sum that is close to, but not exactly, 1.0.
- Missing Components: Some components may not be included in the calculation, leading to an incomplete representation of the mixture.
Solution:
To resolve this warning, you can take the following steps:
Check Mole Fractions: Review the mole fractions of all components in the mixture to ensure they are correctly defined and sum to 1.0. Adjust the values as necessary.
Verify Component Data: Ensure that all components of the gas mixture are correctly defined in the system, including their properties and contributions to the overall mixture.
Review Calculation Settings: Check the settings and parameters used for the calculations to ensure they are appropriate for the mixture being analyzed.
Consult Documentation: Refer to SAP documentation or help resources for specific guidelines on handling gas mixtures and mole fraction calculations.
Test with Known Values: If possible, test the calculations with known values that should yield a sum of 1.0 to verify that the system is functioning correctly.
Contact Support: If the issue persists after checking the above, consider reaching out to SAP support or your internal IT team for further assistance.
Related Information:
By addressing the underlying causes and ensuring accurate data entry, you can resolve the warning and ensure that your calculations are valid.
Get instant SAP help. Start your 7-day free trial now.
O3301
AGA8:Warning code 46: Mole frac.for at least one comp. within warn. range
What causes this issue? One of the molar fractions of the 21 possible components is within the warning range of the AGA c-code routines.System Respon...
O3300
AGA8:Warning code 43: Flowing (material) temp. is within warning range
What causes this issue? The flowing temperature is within the warning range of the AGA c-code. The compression factor will be calculated. The warnin...
O3303
The number & is not in the correct format
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
O3304
Combustion temperature value for target energy is 0; no UoM specified
What causes this issue? A temperature value of zero is passed to the Quantity Conversion Interface (QCI) for a combustion reference temperature of ...
Click on this link to search all SAP messages.