Do you have any question about this error?
Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 299
Message text: AGA8:Warning code 42: Flowing (material) pressure is within warning range
The flowing pressure is within the warning range of the AGA c-code.
The compression factor will be calculated.
The warning range is, according to the AGA c-code documentation:
P / PSIA > 1750 ,
or approx.
P / MPa > 12 .
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
The QCI (Quantity Conversion Interface) continues processing if you
confirm the message.
Error message extract from SAP system. Copyright SAP SE.
O3299
- AGA8:Warning code 42: Flowing (material) pressure is within warning range ?The SAP error message O3299 AGA8: Warning code 42: "Flowing (material) pressure is within warning range" typically relates to the monitoring of pressure in a process or material flow within the SAP system, particularly in the context of process industries or manufacturing environments.
Cause:
This warning indicates that the pressure of a flowing material is currently within a predefined warning range. It does not necessarily indicate a critical failure but serves as a notification that the pressure is approaching a threshold that may require attention. The warning could be triggered by various factors, including:
- Process Variability: Normal fluctuations in the process that cause pressure to rise or fall within the warning range.
- Equipment Calibration: Sensors or equipment may need calibration or maintenance, leading to inaccurate readings.
- Operational Changes: Changes in the operational parameters, such as flow rates or temperature, that affect pressure.
- System Configuration: The warning thresholds may be set too close to normal operating conditions.
Solution:
To address this warning, consider the following steps:
- Monitor the Pressure: Keep an eye on the pressure readings to ensure they do not escalate into a critical range.
- Check Equipment: Inspect the sensors and equipment involved in measuring the pressure to ensure they are functioning correctly and are properly calibrated.
- Review Process Parameters: Analyze the current process parameters to determine if any adjustments can be made to stabilize the pressure.
- Adjust Warning Thresholds: If the warning is frequently triggered without any actual risk, consider reviewing and adjusting the warning thresholds in the system configuration.
- Consult Documentation: Refer to the SAP documentation or system manuals for specific guidance on handling this warning in your particular setup.
Related Information:
If the warning persists or if there are concerns about safety or operational efficiency, it may be advisable to consult with a process engineer or SAP specialist for a more in-depth analysis.
Get instant SAP help. Start your 7-day free trial now.
O3298
AGA8:Error code 39: Sum of mole fractions out of range
What causes this issue? The sum of the mole fractions is larger than 1.020 or smaller than 0.98. The AGA c-code routine cannot calculate a compressio...
O3297
AGA8:Error code 36: Mole frac. for at least one component is out of range
What causes this issue? One of the molar fractions of the 21 possible components is out of the range of the AGA c-code routines.System Response The ...
O3300
AGA8:Warning code 43: Flowing (material) temp. is within warning range
What causes this issue? The flowing temperature is within the warning range of the AGA c-code. The compression factor will be calculated. The warnin...
O3301
AGA8:Warning code 46: Mole frac.for at least one comp. within warn. range
What causes this issue? One of the molar fractions of the 21 possible components is within the warning range of the AGA c-code routines.System Respon...
Click on this link to search all SAP messages.