Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 297
Message text: AGA8:Error code 36: Mole frac. for at least one component is out of range
One of the molar fractions of the 21 possible components is out of the
range of the AGA c-code routines.
The QCI (Quantity Conversion Interface) stops processing
Check the molar fractions of the components. The valid ranges are
(according to the AGA c-code documentation):
Methane: 0.0 to 1.0
Nitrogen: 0.0 to 1.0
Carbon dioxide: 0.0 to 1.0
Ethane: 0.0 to 1.0
Propane: 0.0 to 0.12
Water: 0.0 to 0.10
Hydrogen Sulfide (H2S) : 0.0 to 1.0
Hydrogen: outside 0.0 to 1.0
Carbon monoxide: 0.0 to 0.03
Oxygen: 0.0 to 0.21
Butanes: 0.0 to 0.06
Pentanes: 0.0 to 0.04
Hexanes + : 0.0 to 0.10
Helium: 0.0 to 0.03
Argon: 0.0 to 1.0
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
O3297
- AGA8:Error code 36: Mole frac. for at least one component is out of range ?The SAP error message O3297 AGA8: Error code 36: "Mole frac. for at least one component is out of range" typically occurs in the context of process simulation or chemical engineering calculations within SAP's Advanced Global Application (AGA) module. This error indicates that the mole fraction of one or more components in a mixture is outside the acceptable range, which is usually between 0 and 1.
Cause: Invalid Input Data: The mole fractions of the components in a mixture must sum to 1. If the input data for the mole fractions is incorrect or if the total mole fraction exceeds 1 or is less than 0, this error will occur. Calculation Errors: Errors in the calculations or algorithms used to derive the mole fractions can lead to this issue. Component Definition Issues: If the components are not defined correctly in the system (e.g., missing properties or incorrect phase behavior), it can lead to invalid
Get instant SAP help. Sign up for our Free Essentials Plan.
O3296
AGA8:Error code 33: Flowing (material) temperature is out of range
What causes this issue? The flowing temperature is out of the valid range for the AGA c-code.System Response The QCI (Quantity Conversion Interface)...
O3295
AGA8:Error code 32: Flowing (material) pressure is out of range
What causes this issue? The flowing pressure is out of the valid range for the AGA c-code.System Response The QCI (Quantity Conversion Interface) st...
O3298
AGA8:Error code 39: Sum of mole fractions out of range
What causes this issue? The sum of the mole fractions is larger than 1.020 or smaller than 0.98. The AGA c-code routine cannot calculate a compressio...
O3299
AGA8:Warning code 42: Flowing (material) pressure is within warning range
What causes this issue? The flowing pressure is within the warning range of the AGA c-code. The compression factor will be calculated. The warning r...
Click on this link to search all SAP messages.