Do you have any question about this error?
Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 298
Message text: AGA8:Error code 39: Sum of mole fractions out of range
The sum of the mole fractions is larger than 1.020 or smaller than
0.98. The AGA c-code routine cannot calculate a compression factor.
The QCI (Quantity Conversion Interface) stops processing.
Check the sum of the mole fractions.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
O3298
- AGA8:Error code 39: Sum of mole fractions out of range ?The SAP error message O3298 AGA8: Error code 39: "Sum of mole fractions out of range" typically occurs in the context of process simulation or chemical engineering calculations within SAP's process integration or chemical management modules. This error indicates that the sum of the mole fractions of the components in a mixture does not equal 1, which is a requirement for valid mole fraction calculations.
Cause:
- Incorrect Input Values: The mole fractions of the components in the mixture may have been entered incorrectly, leading to a sum that exceeds or is less than 1.
- Missing Components: Some components may be missing from the input, which can lead to an incorrect total.
- Calculation Errors: There may be errors in the calculations or formulas used to derive the mole fractions.
- Data Entry Errors: Typographical errors during data entry can also lead to this issue.
Solution:
- Check Input Values: Review the mole fractions of all components in the mixture. Ensure that they are correctly entered and that their sum equals 1.
- Verify Component List: Ensure that all components that should be included in the calculation are present and accounted for.
- Recalculate: If the mole fractions are derived from other calculations, verify those calculations to ensure they are correct.
- Consult Documentation: Refer to SAP documentation or help resources for specific guidelines on entering mole fractions and the requirements for the AGA8 calculation.
- Test with Known Values: If possible, test the system with known values that should work to see if the error persists. This can help isolate whether the issue is with the specific data set or a broader system issue.
Related Information:
By following these steps, you should be able to identify and resolve the cause of the error message O3298 AGA8: Error code 39.
Get instant SAP help. Start your 7-day free trial now.
O3297
AGA8:Error code 36: Mole frac. for at least one component is out of range
What causes this issue? One of the molar fractions of the 21 possible components is out of the range of the AGA c-code routines.System Response The ...
O3296
AGA8:Error code 33: Flowing (material) temperature is out of range
What causes this issue? The flowing temperature is out of the valid range for the AGA c-code.System Response The QCI (Quantity Conversion Interface)...
O3299
AGA8:Warning code 42: Flowing (material) pressure is within warning range
What causes this issue? The flowing pressure is within the warning range of the AGA c-code. The compression factor will be calculated. The warning r...
O3300
AGA8:Warning code 43: Flowing (material) temp. is within warning range
What causes this issue? The flowing temperature is within the warning range of the AGA c-code. The compression factor will be calculated. The warnin...
Click on this link to search all SAP messages.