Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 238
Message text: Natural gas base density is not being calculated
The unit of measure of the density test temperature or the density test
pressure is not specified. The Quantity Conversion Interface (QCI)
cannot calculate a base density value using the test density value.
The system will continue processing. If the base density is needed for
the calculation process at a later stage, an error message will be
produced.
This message can be customized to appear as an error, warning or
information message, or can be turned off completely (Trans. O591).
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
Error message extract from SAP system. Copyright SAP SE.
O3238
- Natural gas base density is not being calculated ?The SAP error message O3238, which indicates that "Natural gas base density is not being calculated," typically arises in the context of SAP's Oil and Gas industry solutions, particularly when dealing with the management of natural gas properties.
Cause: The error can occur due to several reasons, including: Missing Configuration: The necessary configuration for calculating the base density of natural gas may not be set up in the system. This could involve missing parameters or settings in the master data for the gas product. Incomplete Master Data: The master data for the natural gas product may be incomplete or incorrect. This includes missing density values or other related properties that are required for the calculation. Calculation Parameters: The parameters or formulas used for calculating the base density may not be defined or may be incorrectly configured. Data Entry Errors: There may be errors in the data entry process, such as incorrect units or values that do
Get instant SAP help. Sign up for our Free Essentials Plan.
O3237
Base density is calculated by the AGA c-code routines
What causes this issue? The QCI has built-in routines that are used to determine the base density if a test density and test conditions are entered. ...
O3236
Unit of measure or parameter is not passed to the QCI
What causes this issue? Before the quantity conversion interface (QCI) can convert quantities, all relevant parameters are checked for consistency. A...
O3239
Natural gas base heating value is not being calculated
What causes this issue? The unit of measure of the calorimeter density test temperature, calorimeter density test pressure or calorimeter combustion...
O3240
Transaction unit of measure is initial
What causes this issue? The system attempts to convert a quantity between two units of measure (Uom). The source or transaction UoM is initial. The c...