Do you have any question about this error?
Message type: E = Error
Message class: O3 - IS-Oil: HPM messages (goods movements, QCI, deliveries)
Message number: 237
Message text: Base density is calculated by the AGA c-code routines
The QCI has built-in routines that are used to determine the base
density if a test density and test conditions are entered. Customers
can modify these calculations using Business Add-In methods. If the
AGA c-code routines are active, the value calculated by the QCI or the
customer function will be overwritten with the value calculated by the
AGA routines.
The system issues an error message and will not allow you to continue with this transaction until the error is resolved.
This message can be customized to appear as an error, warning or
information message (Trans. O591), or can be turned off completely.
Error message extract from SAP system. Copyright SAP SE.
O3237
- Base density is calculated by the AGA c-code routines ?The SAP error message O3237, which states "Base density is calculated by the AGA c-code routines," typically relates to issues in the calculation of base density in the context of gas measurement and reporting within SAP's Oil and Gas (OG) module. This error can arise when the system is unable to compute the base density due to missing or incorrect data or configuration settings.
Cause:
- Missing Configuration: The AGA (American Gas Association) routines require specific configuration settings to calculate base density. If these settings are not properly configured, the error may occur.
- Incorrect Input Data: The input data required for the calculation (such as temperature, pressure, and gas composition) may be missing or incorrect.
- Software Bugs: There may be bugs or issues in the version of the SAP software being used that affect the AGA routines.
- Data Type Mismatch: The data types of the inputs may not match the expected types, leading to calculation failures.
Solution:
- Check Configuration: Ensure that the AGA routines are properly configured in the system. This includes checking the settings for gas measurement and ensuring that all necessary parameters are defined.
- Validate Input Data: Review the input data for the calculation of base density. Ensure that all required fields are filled out correctly and that the data is valid.
- Update Software: If you suspect a bug, check for any available updates or patches for your SAP system that may address this issue.
- Consult Documentation: Refer to the SAP documentation for the Oil and Gas module to ensure that you are following the correct procedures for setting up and using the AGA routines.
- Contact SAP Support: If the issue persists after checking the above points, consider reaching out to SAP support for assistance. They may provide insights specific to your version and configuration.
Related Information:
By following these steps, you should be able to diagnose and resolve the O3237 error in your SAP system.
Get instant SAP help. Start your 7-day free trial now.
O3236
Unit of measure or parameter is not passed to the QCI
What causes this issue? Before the quantity conversion interface (QCI) can convert quantities, all relevant parameters are checked for consistency. A...
O3235
Parameter conversion not supported for product type "chemicals"
Self-Explanatory Message Since SAP believes that this specific error message is 'self-explanatory,' no more information has been given.The majority of...
O3238
Natural gas base density is not being calculated
What causes this issue? The unit of measure of the density test temperature or the density test pressure is not specified. The Quantity Conversion In...
O3239
Natural gas base heating value is not being calculated
What causes this issue? The unit of measure of the calorimeter density test temperature, calorimeter density test pressure or calorimeter combustion...
Click on this link to search all SAP messages.